5-34
2-2-3. OVERALL TAPE PATH CHECK
1. Recording of the tape path check signal
1)
Clean the tape running side (tape guide, capstan shaft, pinch
roller).
2)
Connect the adjustment remote commander to the LANC jack.
3)
Turn the HOLD switch of the adjustment remote commander
to the ON position.
4)
Set to the camera recording mode.
5)
Select page: 3, address: 1C, set data: 5D, and press the PAUSE
button of the adjustment remote commander.
6)
Record for several minutes.
7)
Release the camera recording mode.
8)
Select page: 3, address: 1C, set data: 00, and press the PAUSE
button.
2. Tape path check
1)
Clean the tape running side (tape guide, capstan shaft, pinch
roller).
2)
Connect the adjustment remote commander to the LANC jack.
3)
Turn the HOLD switch of the adjustment remote commander
to the ON position.
4)
Connect an oscilloscope to VC-235 board CN1108 via the CPC-
13 jig (J-6082-443-A).
Channel 1: VC-235 board, CN1108 Pin
qh
(Note)
External trigger: VC-235 board, CN1108 Pin
qd
Note:
Connect a 75
Ω
resistor between Pins
qh
of CN1108
and
6
(GND).
5)
Select page: 2, address: 2E, and set data: 01.
6)
Playback the tape path check signal.
7)
Select page: 3, address: 33, and set data: 08.
8)
Select page: 3, address: 26, and set data: 31.
9)
Check that the oscilloscope RF waveform is flat at the entrance
and exit.
If not flat, perform “2-1-2. TAPE PATH ADJUSTMENT “ of
“2-1. Hi8/STANDARD 8 mm MODE”.
10) Select page: 3, address: 26, and set data: 00.
11) Select page: 3, address: 33, and set data: 00.
12) Select page: 2, address: 2E, and set data: 00.
2-2.
DIGITAL8 MODE
2-2-1. HOW TO ENTER RECORD MODE WITHOUT
CASSETTE
1)
Connect the adjustment remote commander to the LANC jack.
2)
Turn the HOLD switch of the adjustment remote commander
to the ON position.
3)
Close the cassette compartment without the cassette.
4)
Select page: 3, address: 01, and set data: 0C, and press the
PAUSE button of the adjustment remote commander.
(The mechanism enters the record mode automatically)
Note:
The function buttons becomes inoperable.
5)
To quit the record mode, select page: 3, address: 01, set data:
00, and press the PAUSE button of the adjustment remote
commander. (Whenever you want to quit the record mode, be
sure to quit following this procedure)
2-2-2. HOW TO ENTER PLAYBACK MODE WITHOUT
CASSETTE
1)
Connect the adjustment remote commander to the LANC jack.
2)
Turn the HOLD switch of the adjustment remote commander
to the ON position.
3)
Close the cassette compartment without the cassette.
4)
Select page: 3, address: 01, and set data: 0B, and press the
PAUSE button of the adjustment remote commander.
(The mechanism enters the playback mode automatically)
Note:
The function buttons becomes inoperable.
5)
To quit the playback mode, select page: 3, address: 01, set data:
00, and press the PAUSE button of the adjustment remote
commander. (Whenever you want to quit the playback mode,
be sure to quit following this procedure)
Must be flat
Pin
qd
Pin
qh
Fig. 5-2-2
Summary of Contents for DCR-TRV120P
Page 13: ...1 2 ...
Page 14: ...1 3 ...
Page 15: ...1 4 ...
Page 16: ...1 5 ...
Page 17: ...1 6 ...
Page 18: ...1 7 ...
Page 19: ...1 8 ...
Page 20: ...1 9 ...
Page 21: ...1 10 ...
Page 22: ...1 11 ...
Page 23: ...1 12 ...
Page 24: ...1 13 ...
Page 25: ...1 14 ...
Page 26: ...1 15 ...
Page 27: ...1 16 ...
Page 28: ...1 17 ...
Page 29: ...1 18 ...
Page 30: ...1 19 ...
Page 31: ...1 20 ...
Page 32: ...1 21 ...
Page 33: ...1 22 ...
Page 34: ...1 23 ...
Page 35: ...1 24 ...
Page 36: ...1 25 ...
Page 37: ...1 26 ...
Page 38: ...1 27 1 27 E ...
Page 84: ...DCR TRV120 TRV120E TRV120P TRV125E TR8000E TR8100E 4 61 4 62 USER CONTROL CF 69 ...