5-28
1. LCD Initial Data Input (1)
Mode
VTR stop
Signal
Arbitrary
Adjustment Page
C
Adjustment Address
AB to BA
Adjusting method:
1)
Select page: 0, address:01, and set data: 01.
2)
Select page: C, and input the data in the following table.
Note:
To write in the non-volatile memory (EEPROM), press
the PAUSE button of the adjustment remote commander
each time to set the data.
3)
Select page: 0, address:01, and set data: 00.
1-5.
LCD SYSTEM ADJUSTMENTS
(DCR-TRV120/TRV120E/TRV120P/TRV125E)
Note 1:
The back light (fluorescent tube) is driven by a high voltage
AC power supply. Therefore, do not touch the back light
holder to avoid electrical shock.
Note 2:
When replacing the LCD unit, be careful to prevent
damages caused by static electricity.
Note 3:
Set the LCD BRIGHT to the center.
Set the LCD COLOR (Menu display) to the center.
Note 4:
TYPE S 61 k model: DCR-TRV120/TRV120P
TYPE S 123 k model: DCR-TRV120E: AEP, UK, EE,
NE, RU/TRV125E
TYPE C model: DCR-TRV120E: E, HK, AUS, CN, JE
[Adjusting connector]
Most of the measuring points for adjusting the LCD display are
concentrated in the following connector.
CN5502 of the PD-117 board
Connect the Measuring Instruments via the multi CPC jig (J-6082-
311-A).
The following table shows the Pin No. and signal name of the
connector.
[LCD type check]
By measuring the resistor value between Pin
6
of CN5502 and Pin
q;
of CN5502, the type of LCD can be discriminated.
PD-117 board CN5502
Abbreviation
EE
: East European model
NE : North European model
RU : Russian model
HK : Hong Kong model
AUS : Australian model
CN : Chinese model
JE
: Tourist model
Resistor
value
1 k
Ω
1.5 k
Ω
2.2 k
Ω
LCD type
TYPE S 61 k
TYPE C
TYPE S 123 k
Model
DCR-TRV120/TRV120P
DCR-TRV120E: E, HK, AUS,
CN, JE
DCR-TRV120E: AEP, UK, EE,
NE, RU/TRV125E
Pin No.
1
3
5
7
9
Signal Name
VB
VG
VR
C-SYNC/XHD
GND
Pin No.
2
4
6
8
10
Signal Name
XVD OUT
PANEL COM
N.C.
XHD OUT
GND
Address
Data
Remark
AB
53
Fixed data
AC
00
AD
90
AE
CB
AF
66
B0
26
B1
00
B2
00
B3
20
B4
0A
B5
24
B6
1A
B7
08
B8
17
B9
21
BA
23
Summary of Contents for DCR-TRV120P
Page 13: ...1 2 ...
Page 14: ...1 3 ...
Page 15: ...1 4 ...
Page 16: ...1 5 ...
Page 17: ...1 6 ...
Page 18: ...1 7 ...
Page 19: ...1 8 ...
Page 20: ...1 9 ...
Page 21: ...1 10 ...
Page 22: ...1 11 ...
Page 23: ...1 12 ...
Page 24: ...1 13 ...
Page 25: ...1 14 ...
Page 26: ...1 15 ...
Page 27: ...1 16 ...
Page 28: ...1 17 ...
Page 29: ...1 18 ...
Page 30: ...1 19 ...
Page 31: ...1 20 ...
Page 32: ...1 21 ...
Page 33: ...1 22 ...
Page 34: ...1 23 ...
Page 35: ...1 24 ...
Page 36: ...1 25 ...
Page 37: ...1 26 ...
Page 38: ...1 27 1 27 E ...
Page 84: ...DCR TRV120 TRV120E TRV120P TRV125E TR8000E TR8100E 4 61 4 62 USER CONTROL CF 69 ...
Page 88: ...DCR TRV120 TRV120E TRV120P TRV125E TR8000E TR8100E 4 69 4 70 USER CONTROL CF 71 ...