80
Appendix
5B
01
THRESHOLD CONDITION MET
The comparison of set value/accumulated
value of life parameter and log parameter have
met with the specified state.
UNIT
ATTENTION
5B
02
LOG COUNTER AT MAXIMUM
Accumulated value of log parameter is now at
maximum.
UNIT
ATTENTION
80
00
MEDIUM REMOVAL PREVENTED
Removing cartridges are not allowed.
ILLEGAL
REQUEST
The option of cartridge removal is
presently set to PREVENT.
Perform the PREVENT/ ALLOW
MEDIUM REMOVAL command to permit
you to remove cartridges.
80
18
MAGAZINE#1 IS OPEN
There is no magazine on the left.
HARDWARE
ERROR
A magazine is not set on the left.
Insert the left magazine.
80
19
MAGAZINE#2 IS OPEN
There is no magazine on the right.
HARDWARE
ERROR
A magazine is not set on the right.
Insert the right magazine.
80
71
ACCESS DOOR IS OPEN
The front panel has not been locked.
NOT READY
The library cannot be set to the standby
state because the front door is open.
Close the front door.
80
7B
MAIL SLOT IS OPEN
The shutter of the mail slot (import/export slot)
is open.
NOT READY
81
00
MEDIUM PRESENT IN DRIVE
Because cartridges have not been ejected, it is
invalid to remove them from the drive.
ABORTED
COMMAND
84
00
COMMAND SEQUENCE ERROR
A command sequence error occurred.
ABORTED
COMMAND
90
14
I/E ELEMENT FORWARDING ERROR
A moving-forward error occurred in the import/
export element.
HARDWARE
ERROR
Contact the Service and Support Center.
90
15
I/E ELEMENT BACKWARDING ERROR
A moving-backward error occurred in the
import/export element.
HARDWARE
ERROR
Contact the Service and Support Center.
91
20
PICK MEDIUM ERROR
An error occurred when the cartridge was being
shipped from the store slot to the picker
assembly element.
HARDWARE
ERROR
Contact the Service and Support Center.
91
23
STORE MEDIUM ERROR
An error occurred when the cartridge was being
ejected from the picker assembly element to
the store slot.
HARDWARE
ERROR
Contact the Service and Support Center.
91
30
MEDIUM UNLOADING ERROR AT DRIVE
An error occurred when the cartridge was being
shipped from the drive to the picker assembly
element.
HARDWARE
ERROR
Contact the Service and Support Center.
91
32
MEDIUM LOADING ERROR AT DRIVE
An error occurred when the cartridge was being
inserted from the picker assembly element to
the drive.
HARDWARE
ERROR
Contact the Service and Support Center.
92
50
SWING ERROR
An error occurred during the swing operation of
the picker assembly element.
HARDWARE
ERROR
Contact the Service and Support Center.
93
E9
LOGICAL UNIT MEMORY ERROR
Internal memory is unusual.
HARDWARE
ERROR
Contact the Service and Support Center.
ERROR CODE
DESCRIPTION
SENSE KEY
To Recover
ASC
ASCQ