CCU-590/P/V1(E)
2-13
CN902
RV100
RV101
RV102
RV200
RV201
RV202
RV203
RV204
S1
S100 S101
S102
S103
S104 S105
S106
S107
S108
S2
S200
S201
S202
S203
S204
S205
S206
S207
S3
S4
TP202
IC105
A
B
C
D
E
F
G
H
J
K
1
2
3
4
5
AU-295 BOARD (A SIDE)
2-3. Control System
2-3-1. Setting for the Tally System
This unit conforms to red-tally and green-tally systems and
also to contact supply and power supply (24 V/TTL). Set
switches on the AU-295 board according to the tally
system to be used.
Set the switches as follows:
Settings for the tally system
Red tally
Green tally
Switches
S1
S3
S2
S4
Contact
CONTACT
—
CONTACT
—
supply
24 V power
POWER
POWER
POWER
POWER
supply
5 V power
POWER
TTL
POWER
TTL
supply
At the factory, set the switches S1 and S2 on the CCU-590/590P to
CONTACT.
2-4. Video System
The signal levels of the units used in the BVP-E30/E30P
series camera system are set to the standard values at the
factory. Before starting operation, check the levels of the
units, and adjust them if necessary. Basically, adjustment is
performed with the controls and switches on the internal
boards, but some adjustment can be made from the CCU
CONFIGURATION menu. For such items, perform basic
adjustment with the switches and controls on the boards,
and fine adjustment with the CONFIGURATION menu
*
.
*
For how to use the CONFIGURATION menu, refer to Section 2-1. CCU
CONFIGURATION MENU.
2-4-1. Selecting the Input/Output Signal
Select the signal of the input and output connectors in
accordance with the video system to be installed.
Setting the VBS OUT connector
Set the signal output from the VBS/SDI-1 to 3 OUT
connectors on the rear panel by the switch S701 (OUT-
PUT) on the EN board.
VBS/SDI-1 and 3
To output VBS signal: OFF
To output SDI signal:
ON (factory setting)
VBS/SDI-2
To output VBS signal: OFF (factory setting)
To output SDI signal:
ON
Setting the Y/G, R-Y/R and B-Y/B OUT connectors
Set the signal output from the Y/G, R-Y/R and B-Y/B
OUT connectors on the rear panel by the switch S701
(OUTPUT) on the EN board.
To output Y/R-Y/ B-Y signal: ON
To output RGB signal:
OFF (factory setting)
2-4-2. Resetting the Control Data
Before adjustment, reset the control data of the unit.
1.
Open page “C13” of the CCU CONFIGURATION
menu.
2.
Position the cursor at “BACKUP RESET” in the lower
line.
3.
Press ENTER once, “BACKUP RESET OK?” is
displayed.
4.
Press ENTER again to reset the control data.
5.
Be sure to turn off and on the power.