Confidential
MANUAL
18(51)
Document number
Revision
7/198 17-LXE 108 566 Uen
A
Note: Any hard copy of this document is for reference only.
Due to template and application dependencies the header and footer may fail to display correct data. It is the
responsibility of the user to ensure that they have a correct and valid version. Any outdated hard copy is invalid and must be removed from possible use.
2.3.3.3 HW_SD
HW_SD is a bi-directional signal that provides a method of shutting down the module properly (deregistering, etc.)
without using the serial channel.
Limits
Parameter
Symbol
Condition
Minimum
Nominal
Maximum
Units
Input low voltage
V
IL
-0.3 0
0.3*VREF
Input high voltage
V
IH
0.7*VREF
VREF
VREF+0.3
Output low voltage
V
OL
0.22*VREF
Output high voltage
V
OH
0.8*VREF
Volt
Input impedance
inside module
R
IN
Pulled up to
VREF
6
20 34 100
k
Ω
Rise / fall time
t
r
/ t
f
1.0
us
Table 9: HW_SD Electrical Parameters
2.3.3.4 RI
This output signal from the module is used to indicate to the application if an incoming call or SMS is available. A
falling edge indicates incoming call or message. The signal remains low for a period of time before going high. An
SMS-page only generates one pulse which length is configurable using AT*E2SMSRI, while it generates a 1
second low pulse which is repeated during an incoming call until answered or disconnected by the base-station.
Limits
Parameter
Symbol
Condition
Minimum
Maximum
Units
Output low voltage
V
OL
I
L
= 2mA
0
0.22*VREF
Volt
Output high voltage
V
OH
I
L
= 2mA
0.8*VREF
VREF
Volt
Load current
I
L
Source and sink
2
mA
Rise / fall time
t
r
/ t
f
1.0
us
Table 10: RI Electrical Parameters
2.3.3.5 RINGER
The RINGER output signal from the module generates a PWM-ring signal during incoming call. The waveform can
be adjusted by an AT-command.
Limits
Parameter
Symbol
Condition
Minimum
Maximum
Units
Output low voltage
V
OL
I
L
= 5mA
0
0.22*VREF
Volt
Output high voltage
V
OH
I
L
= 5mA
0.8*VREF
VREF
Volt
Load current
I
L
Source and sink
5
mA
Frequency f
4.0
kHz
Rise / fall time
t
r
/ t
f
1.0
us
Table 11: RINGER Electrical Parameters
6
Using a 80
μ
A current pull-up.