Confidential
MANUAL
40(51)
Document number
Revision
7/198 17-LXE 108 566 Uen
A
Note: Any hard copy of this document is for reference only.
Due to template and application dependencies the header and footer may fail to display correct data. It is the
responsibility of the user to ensure that they have a correct and valid version. Any outdated hard copy is invalid and must be removed from possible use.
Single ended Line-level solution:
Apply a DC bias level on the non-inverting input and input the signal through a coupling capacitor on the inverting
input. C4 and R4 determine the HP-filter characteristics, while C5 and R5 determine the LP-filter characteristics.
Figure 25: ATMS Single-ended Recommendation
3.1.6.2 AFMS path
An application using the analog audio interface must re-reference the AFMS-signal from AGND to its own internal
BIAS. The figure shows a differential implementation. C1 is chosen to create the correct HP frequency response.
R1 and R2 determine the gain, and C2 and R2 determine the LP frequency response.
Figure 26: AFMS Recommendation