34
DHY-03 User Handbook
Disconnect Tones – parameters 200,208,216,224,232,240
This value is an indication of the disconnect tone parameters – the tone frequencies and
cadence are only set by changing the parameters below.
Tone Frequency
Value
Type of Tone
Value
350Hz
1
Cadence
16384
400Hz
2
Continuous
32768
425Hz
4
440Hz
8
450Hz
16
480Hz
32
620Hz
64
900Hz
128
User Frequency
8192
Table 3-18 : Table of Disconnect Tone Values.
(Use sum of required values)
Cadence Pattern 1 – parameters 201,209,217,225,233,241
This parameter is set to define a cadence pattern (set to 0 if none). The On time is set in 8ms
steps (i.e. 80ms on time is 10steps) this value is multiplied by 256 and added to the off time.
The off time is also in set in 8ms steps so a cadence pattern of 80ms on and 120ms off is
15 = 2575.
Success Time/Cadence Pattern 2 – parameters 202,210,218,226,234,242
If cadence pattern 1 is zero (i.e. cadence patterns are not set) then this parameter
determines the no of successive tone tests that need to detect the tone before
disconnecting the call. Multiply this value by the number of cycles and divide by 8 for the
time in milliseconds for which the tone must be present before disconnecting.
When cadence pattern is non-zero then this parameter is set in the same way as cadence
pattern 1 above. It is only used when there is a double pattern in the signal cadence.
Cycles for Transform – parameters 203,211,219,227,235,243
Together with the coefficients below this parameter is the number of cycles required by the
DSP to detect the tone(s) accurately. The number is dependant on the tone or combinations
of tones used.
Coefficient for Tone 1 – parameters 204,212,220,228,236,244
This parameter sets the coefficient for the tone detection algorithm.
Coefficient for Tone 2 – parameters 205,213,221,229,237,245
This parameter sets the coefficient for the second tone detection algorithm; if only single
tone detection is required then this parameter should be set to zero.
Threshold Level – parameters 206,214,222,230,238,246
This parameter sets the acceptable level that a tone must be present for successful
detection of that tone to be indicated.
SERIAL PORT CONTROL