2
Rx Level LED
Figure 2-6 : DHY-03EC Controls.
Power LED Indicator
The power LED indicates that the equipment is powered and operational when illuminated.
Gain Jumpers
Refer to Fig 2-8. These jumpers allow gain/attenuation to be applied to the incoming &
outgoing analogue audio. Each jumper has 3 positions, jumper 1-2, off and 3 jumper 2-3
that give gains of -6dB, 0dB & +6dB respectively. The normal position for the transmit gain
to the telephone line (J3 off) is 0db and for the receive gain from telephone line (J4 1-2)
is –6dB.
Tricolour LED Level Indicators
These Tricolour LEDs indicate the signal level of the incoming audio signal (left) and level
received from line (right). For best operation set the signal gain switches to achieve LED
mostly illuminated yellow with occasional audio peaks lighting the red LED.
The scale indicates – Green (-30dB, to -3dB); Yellow (-3dB, to +6dB); & Red (+6dB, LED).