4-16
CCU-TX7 (E)/V1
4-3-9. Y OFFSET Adjustment
Equipment
:
Oscilloscope
To be extended :
YD-26 board
Test point
:
TP11 (GND: E6)/YD-26 board
Adjusting point :
1
RV24 (Y OFFSET ADJ)/
YD-26 board
Specification
:
A = 0
±
3 mV
4-3-10. Y 90˚ Adjustment
Equipment
:
Oscilloscope
To be extended :
YD-26 board
Preparation :
• Select the BARS mode on the RCP-TX7 or COU-TX7.
Test point
:
TP26 (GND: E6)/YD-26 board
Adjusting point :
1
FL3 (90˚ SIFT)/YD-26 board
Specification
:
A = 0
±
10 mV
4-3-11. Y 1st AGC Adjustment
Equipment
:
Oscilloscope
To be extended :
YD-26 board
Preparation :
• S1 (AUTO/MANU)/YD-26 board
→
"AUTO"
• S3 (Y 2nd AGC)/YD-26 board
→
"OFF"
Test point
:
TP11 (GND: E6)/YD-26 board
Adjusting point :
1
RV1 (Y AGC CONT)/YD-26 board
Specification
:
A = 700
±
20 mV
SYNC
A
BLKG
A
[For NTSC]
[For PAL]
A
A