4-9
CCU-TX7 (E)/V1
4-2-13. WF OUT R/B DC OFFSET Adjustment
Equipment
:
Waveform monitor
To be extended :
ES-20 board
Preparation :
• Select the BARS mode on the RCP-TX7.
Test point
:
WF OUT connector/CCU rear panel
Adjustment Procedure :
• Adjust
1
RV511 (R DC BAL),
1
RV514 (B DC BAL)/ES-
20 board so that the DC levels of "R" and "B" are same as
that of "G" even after the MONITOR SELECT button /
RCP-TX7 is selected "R", "G" and "B".
Specification
:
DC level
±
1 mV ("G")
4-2-14. Carrier Balance Adjustment
Equipment
:
Vectorscope (MAX GAIN)
To be extended :
ES-20 board
Preparation :
• Select the BARS mode on the RCP-TX7 or COU-TX7.
Test point
:
VBS 1 OUT connector/CCU rear panel
Adjustment Procedure :
• Adjust
1
RV805 (I (V) CAL) and
1
RV809 (Q(U) CAL)/
ES-20 board so that the luminance point of black level is