background image

7

English

Product description

6

Product description

Supply voltage 

230 V~

Motor type 

24 V

Motor power 

120 W

Maximum power consumption 
(with zone lighting) 

600 W

Consumption in standby mode 

4.5 W

Average frequency of use per day 

20 cycles/day

Length of time to open

*

8 s. to 90°

Automatic detection of obstacles 

Complies with standard EN 12453

Operating temperature 

-20°C to +60°C

Thermal protection 

Yes

Level of Protection 

IP 54

Integrated radio receiver 

Yes

Remote controls:

• Radio frequency 

433.42 MHz

• Range of use 

~ 30 m

• Number of controls memorisable 

16

Possible connections:

• Orange LED output

24 V, 10 W

• Area lighting output, powered contact 

500 W max

• Additional power outputs 

24 Vdc / 200 mA

• Backup battery input 

Yes

• Photoelectric cell input 

Yes 

• Dry contact control input 

Yes

This product is intended for gates to detached houses (described on page 7).

Technical characteristics

Max. weight per leaf (Kg)

200 kg

Max. height per leaf (H)

2  m

Min. width per leaf (W)

0,80 m

Max. width per leaf (W)

2  m

_

* Variable depending on the gate's characteristics.

Kg

W

95

940

175

166

245

310

310

30

Sup. ou égal à 405 mm

90°

Dimensions and maximum weight of 

the leaves

Overall dimension of the SGA (in mm)

Minimum clearance with gate open (in mm)

Greater than or equal to 405 mm

SGA6000 gb.qxd  12/02/08  17:54  Page 6

Summary of Contents for SGA 5000

Page 1: ...differ from actual product SOMFY GMD030110 SOMFY SAS capital of 20 000 000 registered in Bonneville 303 970 230 Utilisable en UE C Usable in EU C Bruikbaar in EU C Utilizable en la UE C Version 3 02 2...

Page 2: ...14 18 13 11 16 5 12 17 15 6 7 19 1 2 3 4 9 8 10 SGA6000 gb qxd 12 02 08 17 54 Page 3...

Page 3: ...1 17 9 8 10 18 15 16 14 13 11 12 5 6 1 2 7 9m 2 x 1 mm2 19 20 SGA6000 gb qxd 12 02 08 17 54 Page 5...

Page 4: ...step installation 1 Preparing and drilling gateposts 12 2 Installing the motors 14 3 Mounting the arms 16 4 Electrical connections 20 5 Settings 23 Usage 29 Troubleshooting 31 Accessories 32 M10 x4 x4...

Page 5: ...t may be used in the European Union and in Switzerland Before installing your product these instructions MUST be read carefully Follow each instruction to the letter and keep this document in your pos...

Page 6: ...memorisable 16 Possible connections Orange LED output 24 V 10 W Area lighting output powered contact 500 W max Additional power outputs 24 Vdc 200 mA Backup battery input Yes Photoelectric cell input...

Page 7: ...gs for the motor drive s arms must be mounted on the horizontal brackets of the leaves at about 1 3 of the height of the gate If there are no such brackets use backing plates approx 4 mm thick Checkin...

Page 8: ...r the weight of vehicles passing over it ref 2400484 Provide a ducted connection between the two gateposts to wire the photocells 2 2 3 1 Bracket Motor M1 Motor M2 2 x 1 mm2 cable between motors 2 x 0...

Page 9: ...asure dimension A Using the table below determine the maximum opening value of the leaves dimension B to determine the vertical positioning axis of the motors on the gateposts D Dimension A mm Maximum...

Page 10: ...motors Position the motor by fastening it onto the lower threaded rods using the washers and nuts 1 Check that the motors are level Continue tightening if necessary 2 Position the motor on the gatepo...

Page 11: ...ide of the arm making sure that their bosses are fully inserted into the arm s grooves 2 Installing the flexible ring in the arm Mounting the arms onto the motors Insert the flexible ring into the arm...

Page 12: ...e fastening lug on the leaves then re install the arms into the fastening lug 5 8 Through the fastening lug mark the points on the leaf bracket where holes will be drilled 3 10 Check that the gate is...

Page 13: ...and closes last Installing the grommets Connecting the two motors Connecting the antenna Connecting the mains power cord Locking the arms M2 M1 Blue Brown Brown Blue Blue Brown Blue Brown Case 1 Moto...

Page 14: ...mplete opening only Both leaves systematically open com pletely with either a short or long press on the remote control Pedestrian or complete opening A single leaf opens to allow pedestrians access w...

Page 15: ...ol your gate Place the remote on the crosshairs inscri bed on the casing Hold down the button to be memorised until the PROG LED blinks slowly the DANGER LED will come on while the button is being hel...

Page 16: ...f the operations to programme the gate s travel path This must be a full cycle 2 complete and uninterrupted openings closings If it is interrupted the process is simply postponed and will resume the n...

Page 17: ...omes on each time the gates are activated They go off automatically 2 minutes after movement has ended STOP Operation in sequential mode Complete opening Make a long press on the remote control Both l...

Page 18: ...Check the transmitter battery Environmental disturbance such as electricity pylons or iron walls Provide for an outside antenna Other problems For all other problems or requests for information about...

Page 19: ...ells are used to halt or reverse the gate s movement if an obstacle is detected A set of photocells may be installed Each set of photocells is comprised of a transmitting cell EC and a receiving cell...

Page 20: ...Accessories Description and connections Digital code 2400581 Key switch 2400597 Intercom 2400463 blue brown white T1 C1 R1 V R3 T2 C2 R2 T3 C3 H P2 M P1 H E V blue brown white T1 C1 R1 V R3 T2 C2 R2...

Page 21: ...576 Remote antenna 2400472 A wider range remote antenna may be used to replace the wire antenna It is to be placed atop the gatepost and must be unencumbered It is connected to the electronic box the...

Reviews: