Programming the remote control memory for complete opening only:

Choose the remote control button you want to use to control your gate.
Place the remote on the crosshairs inscribed
on the casing:

Changing the operating mode for already-programmed remote

controls:

To switch a remote control from "complete opening only" mode to "pedestrian or com-
plete opening
" mode, simply carry out the "Programming remote controls for pedestrian
or complete opening
" operation explained above. The latest programming overwrites the
previous memorised mode.
To switch a remote control from "pedestrian or complete opening" mode to "complete
opening only
" mode, simply use the "Programming remote controls for full opening only"
operation explained above. The latest programming overwrites the previous memorised
mode.

Hold down the button to be memorised 
until the PROG LED blinks slowly (the
DANGER LED 

will come on while the

button is being held).

1

Release the button. It is now memorised. 

2

Programming the remote control memory for pedestrian or complete

opening:

Choose the remote control button you want to use to control your gate.
Place the remote on the crosshairs inscri-
bed on the casing:

Hold down the button to be memorised
until the PROG LED blinks slowly (the
DANGER LED 

will come on while the

button is being held).

1

Release the button.

2

Within 10 seconds, press again on the button to be memorised until the PROG LED blinks
slowly (the DANGER LED 

will come on while the button is being held).

3

Release the button. It is now memorised. 

4

Once the programming cycle is complete, only the PROG and ON/OFF LEDs will be
lit, with the electronics on standby to record the leaves' travel.

All settings that have been recorded are deleted, including remote controls programmed, the
gate's travel and the operating mode.

Subsequent adding of remote controls 

Repeat the steps given in "Programming remote controls" (see  page 24).

Over and above 16 transmitters, programming will fail. Delete all controls (see
above) and reprogramme.

Programming a new remote control cancels the previous programmed gate travel.
Start "Learning the leaves' travel" again 
(see page 26).

Deprogramming remote controls

• Press the reset button and hold it for 7 seconds.
> As you do, all four LEDs will come on.

1

• Release the reset button.
> All four LEDswill go off for two seconds.
> The ON/OFF LED will come on again.
> The PROG LED will come on again.

2

LEDs 

reset button

SGA6000 gb.qxd  12/02/08  17:54  Page 24

Summary of Contents for SGA 5000

Page 1: ...differ from actual product SOMFY GMD030110 SOMFY SAS capital of 20 000 000 registered in Bonneville 303 970 230 Utilisable en UE C Usable in EU C Bruikbaar in EU C Utilizable en la UE C Version 3 02 2...

Page 2: ...14 18 13 11 16 5 12 17 15 6 7 19 1 2 3 4 9 8 10 SGA6000 gb qxd 12 02 08 17 54 Page 3...

Page 3: ...1 17 9 8 10 18 15 16 14 13 11 12 5 6 1 2 7 9m 2 x 1 mm2 19 20 SGA6000 gb qxd 12 02 08 17 54 Page 5...

Page 4: ...step installation 1 Preparing and drilling gateposts 12 2 Installing the motors 14 3 Mounting the arms 16 4 Electrical connections 20 5 Settings 23 Usage 29 Troubleshooting 31 Accessories 32 M10 x4 x4...

Page 5: ...t may be used in the European Union and in Switzerland Before installing your product these instructions MUST be read carefully Follow each instruction to the letter and keep this document in your pos...

Page 6: ...memorisable 16 Possible connections Orange LED output 24 V 10 W Area lighting output powered contact 500 W max Additional power outputs 24 Vdc 200 mA Backup battery input Yes Photoelectric cell input...

Page 7: ...gs for the motor drive s arms must be mounted on the horizontal brackets of the leaves at about 1 3 of the height of the gate If there are no such brackets use backing plates approx 4 mm thick Checkin...

Page 8: ...r the weight of vehicles passing over it ref 2400484 Provide a ducted connection between the two gateposts to wire the photocells 2 2 3 1 Bracket Motor M1 Motor M2 2 x 1 mm2 cable between motors 2 x 0...

Page 9: ...asure dimension A Using the table below determine the maximum opening value of the leaves dimension B to determine the vertical positioning axis of the motors on the gateposts D Dimension A mm Maximum...

Page 10: ...motors Position the motor by fastening it onto the lower threaded rods using the washers and nuts 1 Check that the motors are level Continue tightening if necessary 2 Position the motor on the gatepo...

Page 11: ...ide of the arm making sure that their bosses are fully inserted into the arm s grooves 2 Installing the flexible ring in the arm Mounting the arms onto the motors Insert the flexible ring into the arm...

Page 12: ...e fastening lug on the leaves then re install the arms into the fastening lug 5 8 Through the fastening lug mark the points on the leaf bracket where holes will be drilled 3 10 Check that the gate is...

Page 13: ...and closes last Installing the grommets Connecting the two motors Connecting the antenna Connecting the mains power cord Locking the arms M2 M1 Blue Brown Brown Blue Blue Brown Blue Brown Case 1 Moto...

Page 14: ...mplete opening only Both leaves systematically open com pletely with either a short or long press on the remote control Pedestrian or complete opening A single leaf opens to allow pedestrians access w...

Page 15: ...ol your gate Place the remote on the crosshairs inscri bed on the casing Hold down the button to be memorised until the PROG LED blinks slowly the DANGER LED will come on while the button is being hel...

Page 16: ...f the operations to programme the gate s travel path This must be a full cycle 2 complete and uninterrupted openings closings If it is interrupted the process is simply postponed and will resume the n...

Page 17: ...omes on each time the gates are activated They go off automatically 2 minutes after movement has ended STOP Operation in sequential mode Complete opening Make a long press on the remote control Both l...

Page 18: ...Check the transmitter battery Environmental disturbance such as electricity pylons or iron walls Provide for an outside antenna Other problems For all other problems or requests for information about...

Page 19: ...ells are used to halt or reverse the gate s movement if an obstacle is detected A set of photocells may be installed Each set of photocells is comprised of a transmitting cell EC and a receiving cell...

Page 20: ...Accessories Description and connections Digital code 2400581 Key switch 2400597 Intercom 2400463 blue brown white T1 C1 R1 V R3 T2 C2 R2 T3 C3 H P2 M P1 H E V blue brown white T1 C1 R1 V R3 T2 C2 R2...

Page 21: ...576 Remote antenna 2400472 A wider range remote antenna may be used to replace the wire antenna It is to be placed atop the gatepost and must be unencumbered It is connected to the electronic box the...