27
English
Settings
5
26
Settings
5
●
Checking that settings are correct
Make a long press on the remote control.
Press the button again so that both leaves stop midway through their travel.
Cut mains power for at least 5 seconds.
Restore mains power.
Make another long press on the remote control.
The leaves MUST continue in the opening direction.
If the leaf does not open correctly:
• The leaf which moves first (controlled by M1) starts to close
Invert wires A and B on motor M1.
• The gate which moves second (controlled by M2) starts to close
Invert wires A and B on motor M2.
After inverting the wiring on one or two motors, the leaf travel learning procedure will
have to be carried out again.
5
4
3
2
1
❏
Learning the leaves' travel.
Somfy's electronics automatically memorise:
• The motor torque needed to control the gates when operating normally.
This programming subsequently enables any abnormal strain on the motorisation to be
detected.
• The travel required for the complete opening and closing of the leaves with location
marking of the stops.
To begin the programming process, the leaves must be closed. Keep at a normal distance
from the gate and follow the steps below:
Once these 4 steps have been completed, the PROG LED goes off, indicating the end of the
operations to programme the gate's travel path.
This must be a full cycle (2 complete and uninterrupted openings/closings). If it is interrupted,
the process is simply postponed, and will resume the next time the gate is opened.
• Make a long press on the remote
control button.
> After a few seconds, the gates will
slowly open.
* If the gate does not open correctly,
check that the motors are wired as
shown on the following page.
1
• Once the gate is open, make another
long press on the remote control
button.
> The gate closes, one leaf after the
other.
2
• Press the same button again.
> The gates open, still at a slow speed.
3
• Press the button one last time.
> The two leaves will close almost
simultaneously.
4
• Make a long press on the remote
control button until the AUTO LED
comes on. Release the button.
> The AUTO LED blinks.
2
• Place a remote control on the
crosshairs inscribed on the motor
unit's casing.
> The AUTO LED is off.
1
●
Automatic mode
After opening, the gates close again automatically after a preset length of time
.
Automatic mode will function after the cells have
been wired and configured as below:
❏
Automatic mode settings.
●
Usage precautions
To use your gate in automatic mode, the standard EN 12453 requires that the following
accessories be installed. Your SGA is designed to be
connected to them :
• a set of photocells (see description and wiring on page
32),
• an orange LED (see description and wiring on page 33),
• zone lighting.
SGA6000 gb.qxd 12/02/08 17:54 Page 26