7
EN
Oximo 40 Solar io
Copyright
©
2021 SOMFY ACTIVITES SA, Société Anonyme. All rights reserved.
Setting the end limits in semi-automatic mode (2.3.4.c)
Setting the upper end limit in automatic mode and the lower
end limit in manual mode
1) Lower the motorised product to the desired position by
pressing the
Down
button.
2) Press the
my
and
Up
buttons simultaneously until the
motorised product rises; the lower end limit is set.
3) Press the "
my
" button to stop the motorised product.
4) To confirm the end limits, press the
my
button until the
motorised product moves up and down.
Setting the upper end limit in manual mode and the lower end
limit in automatic mode
1) Raise the motorised product to the desired upper position by
pressing the
Up
button.
2) Press the
my
and
Down
buttons simultaneously until the
motorised product lowers; the upper end limit is set.
3) Press the "
my
" button to stop the motorised product.
4) To confirm the end limits, press the
my
button until the
motorised product moves up and down.
2.3.5. Programming the control point
The drive is in programming mode:
-
Briefly press the PROG button on the control point to be
programmed:
The motorised product moves up and down: this control
point is programmed in the drive.
͉
If the drive is no longer in programming mode, repeat Step 2.3.1
before performing Step 2.3.5.
2.3.6. Re-setting the end limits (for end limits set in manual mode)
Readjusting the upper end limit
1) Press the
Up
button to bring the motorised product to the end
limit to be readjusted.
2) Press the
Up
and
Down
buttons at the same time until the
motorised product moves up and down.
3) Press the
Up
or
Down
button to move the motorised product
to the new desired position.
4) To confirm the new end limit, press the
my
button until the
motorised product moves up and down.
1)
2)
3)
4)
1 2
4 3
PROG. 0.5
s
1)
2)
3)
4)
1)
2)
3)
4)