background image

3

 - be fitted with a lightning conductor (in compliance with standard NF C 61740, maximum residual voltage 2 kV),

 Check whether the earthing system is installed correctly: connect all the metal parts of the assembly and all the components of the installation equipped 

with earth terminals.
 After installation, ensure that the mechanism is correctly adjusted and that the protection system and any manual release mechanism operate correctly.

Safety devices

 The selected safety accessories for the installation must comply with the current standards and regulations in force in the country in which the product is 

being installed. The use of any safety components not approved by Somfy remains the sole responsibility of the installer.
 Install all the safety devices (photoelectric cells, safety edges, etc.) required to protect the zone from the danger of crushing, entanglement and cutting 

according to the applicable directives and technical standards.
 In accordance with standard EN 12453 governing the safe use of motorised gates and doors, the use of the TAHOMA control box to automatically control a 

garage door or gate not visible to the user requires the installation of a photoelectric cell type safety device with autotest on the automatic control system.

maintenance

 Regularly check the condition of the gate. Gates in poor condition must be repaired, reinforced or even replaced. Check that the various motorisation 

component's screws and fittings are correctly tightened.

Before carrying out work on the installation, switch off the power supply.
Use only original parts for any maintenance or repair work. 

PrOduCT dESCrIPTION

 Size of motor (in mm)

166.12

175

938.83

309.

9

245

30.

5

297.

5

Technical data

Power supply

230 V - 50/60 Hz

Standby power consumption (excluding accessories)

2.6 W

Standby solar power consumption

1 W

Max. power consumption

600 W

Average frequency of movements per day

20 cycles/day

Max. thrust force at 1.25 m

< 15 kg EN 12453

Operating temperature

-20°C to +60°C

Thermal protection

Yes

Index protection rating

IP 44

Integrated radio receiver

Yes

Number of storable remote controls

16

Motor feed outputs

24 V DC

Power per motor

120 W

Output for orange light

Flashing, 24 V, 15 W

Area lighting output

500 W max.

Accessories supply output

24 V CC/1 A (including orange light)

Backup battery input

Yes

Photoelectric cell input

Yes (1 or 2 sets)

Dry contact input 

Yes

Summary of Contents for HOME MOTION Axovia 220B

Page 1: ...EN Installation instructions Axovia 220B...

Page 2: ...ower stop cover x 2 8 Information card x 1 23 End stop bolt x 6 9 Enclosure cover x 2 24 End stop upper part lower part x 2 10 O ring x 2 25 Motor arm gate leaf arm short shaft x 2 11 Cover bolt x 2 2...

Page 3: ...iring 9 Mains cable connection 9 Locking the arms 10 Switching the installation on 10 quick commissioning_______________________________________________________________ 10 Storing the remote controls...

Page 4: ...out the operation of the control systems and the manual opening procedure in the event of an emergency Installations which do not comply with the specifications in this manual or improper use of the p...

Page 5: ...ntrol a garage door or gate not visible to the user requires the installation of a photoelectric cell type safety device with autotest on the automatic control system Maintenance Regularly check the c...

Page 6: ...inforcements prepare some metal reinforcement plates e g 15x15 cm and 4 cm thick to secure the brackets to the gate leaves 1 25 L 2m H 2m P 200kg RESET RADIO RESET RADIO indicator light Operating diag...

Page 7: ...s AM on the pillar copying dimension B on the pillar 65 mm 175 mm 455 mm 355 mm 6 Trace horizontal line AH in the middle of the reinforcement perpendicular to the rotational axis of the gate If the ga...

Page 8: ...improved legibility use a permanent marker na me tel name tel 3 Attach the motor checking the level 4 Assemble the motor arm to the motor with an HM 10x40 bolt 20 the gate leaf arm to the motor arm w...

Page 9: ...einforcement the gate arm marking must be lined up with the motor arm arrow Ensure the markers on the motor arm and the gate arm are lined up to ensure the gate is properly closed and can withstand st...

Page 10: ...2 mm towards the motor arm shoulder 5 Tighten the end stop with a long Allen key for greater torque when tightening the end stop bolts 16 Nm 6 Install the end stop covers screw the lower cover with ho...

Page 11: ...1 is to the left and M2 to the right If M1 is to the right and M2 to the left connect the wire of to terminal connect the wire of to terminal M1 blue 9 M1 brown 9 brown 10 blue 10 M2 brown 11 M2 blue...

Page 12: ...estrian opening on one button 1 Position the remote control on the target engraved on the cover 2 Briefly press the button on the remote control to be activated to open the gate in pedestrian mode The...

Page 13: ...press the programmed button on the remote control again The gate closes one gate leaf at a time 4 Initiate a second opening and closing cycle This time the two gate leaves will close at the same time...

Page 14: ...1 2 3 4 1 2 3 4 1 2 3 4 1 Place a programmed remote control on the target engraved on the cover 2 Press button 1 on the remote control until the indicator light flashes 3 Press button 2 on the remote...

Page 15: ...p 230Vac General wiring diagram Connecting the photoelectric cells Photoelectric cells must be connected to use the motor in automatic closing mode Ant BU S Ce ll 2 4 V dc 1 3 5 7 9 11 2 4 6 8 10 Fla...

Page 16: ...2 3 5 RX2 TX Transmitter cell RX Receiver cell 2 sets of photoelectric cells RX RX TX RX RX TX TX TX Recognition of the cells by the motor electronics The cells are recognised by revalidating the mot...

Page 17: ...ke worn batteries to the appropriate sites for proper disposal If there is a power cut and the backup battery is not charged you will not be able to open your gate If your gate is the only entrance to...

Page 18: ...he gate is barred we would suggest you protect the access to the arm from the outside of the property In order to limit the energy consumption of your gate motor we recommend the gate be closed to opt...

Page 19: ...wired Wire the cells following the instructions on page 13 or 14 Cells missing disconnected Check that the cells are correctly connected If you have deliberately disconnected the cells and your gate...

Page 20: ...button 1 on the remote control until the indicator light flashes 3 Press button 1 on the remote control once The RESET indicator light flashes 4 Press button 2 on the remote control until the RESET i...

Page 21: ...______________________________________________________________ 2 Recycling___________________________________________________________________________ 2 Use and operation_______________________________...

Page 22: ...mage that may be caused Any use outside the sphere of application specified by Somfy is forbidden This invalidates the warranty and discharges Somfy of all liability as does any failure to comply with...

Page 23: ...has been programmed during installation the gate will operate as follows Pressing a programmed button on the remote control will cause the gate to open The gate will close automatically after 30 seco...

Page 24: ...d goes out 1 minute and 30 seconds after the motor has come to a complete stop Operation using the backup battery If a backup battery is installed the motorisation will work even during a power outage...

Page 25: ...5...

Page 26: ...66 1 47 23 203 Jeddah 966 2 69 83 353 Kuwait Somfy Kuwait 00965 4348906 Lebanon Somfy Middle East 961 0 1 391 224 Malaisia Somfy Malaisia 60 0 3 228 74743 Mexico Somfy Mexico SA de CV 52 0 55 5576 342...

Reviews: