4
Area of application
This product is intended for the motorisation of a hinged gate for an individual
home.
description of operation of the indicators
PrE-INSTAllATION ChECkS
Gate
The gate must be in good condition: ensure that its structure is suitable for automatic control and that it conforms to the relevant standards.
The gate must remain horizontal throughout its travel, and must open and close manually with ease.
Pillars
The pillars are untrue so require the use of an intermediate plate.
Furthermore, when one of the motor clamp mounting holes is not resting on anything or is close to the angle of the pillar or wall, it is essential to use the
intermediate plate (ref. 2400485).
reinforcements
If the gate has no reinforcements, prepare some metal reinforcement plates (e.g.: 15x15 cm and 4 cm thick) to secure the brackets to the gate leaves.
1.25 < L ≤ 2m
H ≤ 2m
P ≤ 200kg
=
=
RESET
RADI
O
=
=
RESET
RADI
O
=
=
indicator light
Operating diagnostics
Off:
Motor not supplied or on standby
Continuously lit:
Motor operational
Flashing:
See diagnostic table on page 17
indicator light
Automatic closing
Off:
Automatic closing mode not activated
Continuously lit:
Automatic closing mode activated
Flashing:
Awaiting activation/deactivation of automatic closing
mode
rAdIO indicator light
Radio frame received
Off:
No radio reception
Lit:
Radio command received
indicator light
Pedestrian opening
On:
Lights up when pedestrian opening is activated/
deactivated using one of the remote control buttons
rESET indicator light
Clearing settings/transmitters
Continuously lit:
Awaiting clearing order for settings and/or transmitters
Flashing:
Settings and/or transmitters cleared