background image

EN 13241
EN 12453
EN 12445

Junior 624

24 Vdc

ELPRO 64

   1 - 18

I

Libretto di istruzioni

19 - 36

GB

Instructions manual

pages

37 - 54

F

Notice d’instructions

page

pag.

Summary of Contents for Junior 624

Page 1: ...EN 13241 EN 12453 EN 12445 Junior 624 24 Vdc ELPRO 64 1 18 I Libretto di istruzioni 19 36 GB Instructions manual pages 37 54 F Notice d instructions page pag...

Page 2: ...nea 230 V 50 Hz magneto termico differenziale da 0 03 A Utilizzare corpi di prova idonei per le prove di funzionamento nella rilevazione della presenza in prossimit o interposti ai dispositivi di sicu...

Page 3: ...dotto il Costruttore dichiara sotto la propria responsabilit il rispetto della NORMATIVA DI PRODOTTO EN 13241 1 Testato e certificato marcatura con prove di tipo ITT PDC 0976 2010 30 04 2010 Organismo...

Page 4: ...tore R Trasformatore 230 V 24 V 150 VA per Junior 624 1 Fotocellula ricevitore 2 Battuta di arresto 3 Fotocellula proiettore 4 Junior 624 con programmatore e radio ricevente da innesto 5 Interruttore...

Page 5: ...N PIASTRA DI FONDAZIONE FISSAGGIO CON TASSELLI non in dotazione Fig 7 Fig 6 ATTENZIONE tolte le due viti laterali alzare il cofano di copertura e sfilare verticalmente senza strappare il connettore de...

Page 6: ...l interno dell impianto possibile effettuare ci spostando il dip switch n 11 del programmatore Elpro 64 gi installato a bordo su Junior 624 in ON oppure in OFF Fig 10 1 7 2 mm ATTENZIONE togliere alim...

Page 7: ...non aprire e invertire i singoli magneti interni alle plastiche delle staffe dei finecorsa essi sono gi correttamente installati per essere identificati dalla logica del programmatore ATTENZIONE FOND...

Page 8: ...strati anche nei fogli d istruzione dei singoli accessori JUNIOR 624 Trasformatore Morsettiera con fusibile Encoder 230 V NERO BIANCO 22 V 5 A Motore 24 V Motore Batteria 12 V 2 3 Ah Batteria 12 V 2 3...

Page 9: ...automatico con rallentamenti programmabili Possibilit radio passo passo radio non inverte in apertura con o senza prelampeggio inversione di marcia all urto con l ostacolo diagnostica a led definizion...

Page 10: ...con un lampeggio alternato blu arancione Collegando un qualsiasi contatto NA tra i due morsetti si pu ottenere ad ogni impulso Solo apertura dip 2 ON e dip 5 OFF Inversione di marcia ad ogni impulso d...

Page 11: ...due ante non sono lunghe uguali installare Elpro 64 MASTER sull anta pi lunga Si rimanda alle pagine precedenti la composizione dei dip switch relativi ai singoli accessori e funzioni 12 DIP SWITCH 12...

Page 12: ...e coste di sicurezza Ogni eventuale guasto o perdita di efficienza verr segnalato tramite il lampeggio dei led L21 e L24 In caso di ostacolo rilevato a seguito dell intervento delle coste di sicurezza...

Page 13: ...i di sicurezza affinch siano correttamente funzionanti In caso contrario l automazione non parte e viene segnalato sul carter del Junior con un lampeggio alternato blu arancione Apertura mediante orol...

Page 14: ...a e rendere libero il cancello dal Junior quindi posizionare il cancello a circa met della sua corsa Ripristinare il blocco chiudendo la maniglia Come sicurezza quando viene liberata la maniglia di sb...

Page 15: ...funzionamento resti di insetti fogliame piccoli sassi ecc prima di procedere togliere alimentazione elettrica dall impianto effettuare regolarmente la pulizia delle apparecchiature servendosi unicame...

Page 16: ...ensioni dell anta Peso singola anta Data di installazione Quantit dei modelli installati Manutentore Data ATTENZIONE questo documento deve contenere gli interventi ordinari e straordinari di installaz...

Page 17: ...ancello pu andare a sbattere contro le battute di arresto regolare le staffe dei finecorsa vedere pag 7 Chiudere e rimuovere la chiave dalla serratura Led sul carter lampeggia BLU Per 5 volte consecut...

Page 18: ...ura chiusura 30 s pausa Tempo di un ciclo completo 120 s max 30 cicli ora Tempo di un ciclo completo 120 s max 30 cicli ora A La struttura la forma e le ruote del cancello possono ridurre i valori ind...

Page 19: ...EN 13241 EN 12453 EN 12445 19 36 GB Instructions manual pages the gate opener 19 Junior 624 24 Vdc ELPRO 64...

Page 20: ...mal magnetic circuit breaker 0 03 A 230 V 50 Hz upstream the installation Use appropriate objects to test the correct functionality of the safety accessories such as photocells sensitive edges etc Car...

Page 21: ...order to certify the product the manufacturer declares under own responsibility the compliance with the EN 13241 1 PRODUCT NORMS Tested and certified marking and type testing according to ITT PDC 0976...

Page 22: ...iction or resistance JUNIOR 624 Pic 2 A Led light blue and amber colours for automation status indication B Casing fixing screws C Casing D Power cord for LED E Elpro 64 programmer for Junior 624 F Pr...

Page 23: ...TH A BASE PLATE ANCHORING WITH PLUGS not supplied Pic 7 Pic 6 ATTENTION once the two side screws have been removed lift the casing and vertically pull it out without tearing off the led card cable con...

Page 24: ...moving dip switch n 11 on the Elpro 64 programmer already installed on the Junior 624 depending on the position of Junior as seen inside the gate to be opened Pic 10 1 7 2 mm opening direction opening...

Page 25: ...itch ATTENTION do not open and invert the single magnets inside the limit switch plastic brackets These have already been properly installed to be identified by programmer logic NOTE WELL IT IS MOST I...

Page 26: ...tch Connector limit switch ro 64 for Junior 624 24 Vdc A B C Junior 624 max 400 kg Transformer Terminals with fuse Encoder 230 V BLACK WHITE 22 V 5 A Motor 24 V Motor Battery 12 V 2 3 Ah Battery 12 V...

Page 27: ...it performs the function for open pause close in automatic or semi automatic with programmable slowdown possibility of step by step radio command radio no reverse on opening with or without pre flashi...

Page 28: ...nd NC contacts to be connected to the respective terminals of the key or button switches All the possible configurations are attached to their respective command accessories L4 red off no contact OPEN...

Page 29: ...efer to the previous pages for the dip switch arrangements relative to the individual accessories and functions 12 DIP SWITCH 12 ON Elpro 64 SLAVE 2nd Junior 624 OFF Elpro 64 MASTER 1st Junior 624 L21...

Page 30: ...efficiency is signalled by the L21 and L24 LEDs keeping flashing In case an obstacle is detected by the safety edges or photocells in opening phase the gate travel is reversed a little bit so that the...

Page 31: ...the operator is prevented from starting and the LED on the Junior cover keeps flashing with alternated blue and orange lights Opening by way of external clock Connection connect the NO contact of the...

Page 32: ...til it stops beyond 90 thus freeing the gate from the Junior operator Then push the gate at about halfway of its run Reset locking condition by closing the handle As safety measure when the release ha...

Page 33: ...uipment by using a damp cloth Do not use flammable substances such as alcohol solvents or benzene these substances may cause explosions and or damage the system MAINTENANCE 2 3 1 This manual operation...

Page 34: ...ns per gate leaf Weight per gate leaf Installation date Quantity of models installed Maintainer Date NOTE WELL this document must record any ordinary and extraordinary services including installation...

Page 35: ...ted during the gate movement for 5 consecutive times Remove obstacles and give an opening closing command Remove possible causes of friction on the sliding gate track guides The gate might have run in...

Page 36: ...3 000 rpm p Gate speed 12 m min Gear ratio 1 61 d d Protection standards IP 54 Oil type oil FADINI code 706L Working temperature Working temperature 20 C 50 C Weight 11 kg Frequency of use intensive F...

Page 37: ...EN 13241 EN 12453 EN 12445 37 54 F Notice d instructions page 37 l ouvre portail Junior 624 24 Vdc ELPRO 64...

Page 38: ...n amont de l installation d un interrupteur diff rentiel magn tothermique de 0 03 A de courant 230 V 50 Hz Utiliser des objets appropri pour effectuer les tests de fonctionnement des photocellules d t...

Page 39: ...onformit la NORME PRODUIT EN 13241 1 Test et certifi marquage avec essais de type ITT PDC 0976 2010 30 04 2010 Organisme et laboratoire notificatif pour la certification du produit selon DM 2004 108 C...

Page 40: ...nt led bleue et ambre pour la signalisation de l tat de l automation B Vis de fixation du coffre C Coffre de couverture D C ble d alimentation LED E Programmateur Elpro 64 pour Junior 624 F Support du...

Page 41: ...couverture et l extraire verticalement sans rompre le connecteur du c ble de la carte led Placer et fixer la plaque de fondation une distance de 60 mm du portail ouvrir en la nivelant plat Il est impo...

Page 42: ...Elpro 64 d j install dans le Junior 624 selon la position du Junior vu de l int rieur du portail ouvrir Fig 10 1 7 2 mm direction d ouverture direction d ouverture Junior install GAUCHE placer le dip...

Page 43: ...int rieur des plastiques des triers des fins de course ils sont d j correctement install s pour tre identifi s par la logique du programmateur ATTENTION IL EST ESSENTIEL QUE LE PORTAIL NE HEURTE PAS C...

Page 44: ...ation Trimmer force Led fin de course Enclenchement fin de course ro 64 pour Junior 624 24 Vdc A B C Junior 624 max 400 kg Transformateur Plaque bornes avec fusible Encoder 230 V NOIR BLANC 22 V 5 A M...

Page 45: ...ssement programmable la possibilit de radio pas pas radio n inverse pas l ouverture avec ou sans pr clignotement inversion de marche en cas d obstacle et contr le par led d finition au moyen de dip sw...

Page 46: ...tocellules doivent tre n cessairement aliment s par les sorties 13 14 OFF aucun contr le DSA des photocellules NF NF 1 2 Tous les contacts NF des photocellules en phase de fermeture doivent tre raccor...

Page 47: ...witch relatifs chaque accessoire et chaque fonction COMMUN OUVRE FERME ARRET 12 DIP SWITCH 12 ON Elpro 64 SLAVE 2 me Junior 624 OFF Elpro 64 MASTER 1er Junior 624 L21 L22 L24 vertes allum es sur tous...

Page 48: ...efficacit est signal par le clignotement continu des LED L21 et L24 En cas d obstacle d tect par les listeaux de s curit ou photocellule l ouverture le portail inverse sa marche pour une courte distan...

Page 49: ...ment En cas contraire l automation ne part pas et sur le carter du Junior il y a un clignotement de couleur bleue et orange Ouverture par horloge ext rieure Raccordement raccorder en parall le le cont...

Page 50: ...de d verrouillage au moyen de la cl cod e et lib rer le portail du Junior puis positionner le portail environ la moiti de sa course R tablir le verrouillage en fermant le levier Pour des raisons de s...

Page 51: ...e nettoyez r guli rement l quipement en utilisant uniquement un chiffon humide N utilisez pas de substances inflammables ni d alcool de diluants de benz ne ces substances pourraient provoquer des expl...

Page 52: ...de fabrication Quantit mod les install s Mainteneur Date ATTENTION Ce document contient le registre des installations entretiens r parations et am liorations ordinaires et extraordinaires tout fait e...

Page 53: ...pports de fin de course voir page 43 Fermer et enlever la cl de la serrure La lampe led sur le carter est BLEUE et clignote Pour 5 fois cons cutives on a d tect la pr sence d un obstacle ou de possibl...

Page 54: ...oteur 3 000 rpm Vitesse 12 m min Rapport 1 61 Degr de protection Degr de protection IP 54 Huile oil FADINI code 706L Temp rature de service Temp rature de service 20 C 50 C Poids 11 kg Fr quence d uti...

Page 55: ...55 JUNIOR 624...

Page 56: ...ali elettrici ed elettronici VIETA T T T A A O GETTARE NEI RIFIUTI T T MATERIALI NOCIVI PER A A L L LAMBIENTE I Via Mantova 177 A 37053 Cerea VR Italy Ph 39 0442 330422 Fax 39 0442 331054 info f f fad...

Reviews: