Connection to the power supply
To connect the motor to the power supply, use a standard, multicore cable with a minimum
cross section of 3x1.5 mm².
Inputs 23, 24 and 25 must be bridged to terminal 21 if they are not used to
connect a safety device.
Check the motor wiring
motorisation to the left (a)
motorisation to the right (B)
Wire
Terminal
Terminal
motor connection
Red
1
2
Blue
2
1
End limit connection
Brown
6
7
Red
7
6
Black
5
5
switch on the power to the installation before commissioning.
installer interface
Parameter setting is carried out using the buttons on the control unit
language selection
Press the OK button. Information is displayed on the screen (information
[1]
details - pg. 12).
Press the OK button.
[2]
Use the + and - buttons on the control unit to access the "LAnGUE" (Language)
[3]
menu.
Press the OK button.
[4]
Use the + and - buttons to access the required language.
[5]
Press the OK button to confirm your selection.
[6]