6
Copyright © 2008 Somfy SAS. All rights reserved.
EN
Elixo 500 24 V
fitting the end limit brackets
Manually move the gate to the open position.
[1]
Position a bracket onto the rack so that it activates the motor end limit contact.
[2]
Screw the bracket onto the rack.
[3]
Manually move the gate to the closed position then repeat steps 2 and 3 to fit
[4]
the second bracket to the rack.
Wiring
General wiring diagram
terminals
description
function
1-2
A-B
Motor connection
3-4
0V-24V~
Secondary transformer
5
COM
Shared by end limit contacts
6
SWC
Closing end limit contact
7
SWO
Opening end limit contact
8-9
24 V output, flashing orange light
10
ANT
Aerial core
11
ANT
Aerial braid
12-13
24 V~/
---
Alternating 24 V output for power supply to the additional devices
14-15
SCA
Gate status indicator output (open/closed)
16-17
24 V~/
---
(V Safe)
Alternative 24 V output for power supply to, and autotest of, safety devices
18
FAULT
Input for safety devices autotest
19
COM
Shared by control inputs (18-20)
20
PED
Pedestrian opening control point input
21
COM
Shared by control inputs (22-23-24-25-26)
22
START/CLOSE
Sequential operation control point input (adjustable in the LoGic menu, see pg.11)
23
STOP
Control point input (closing only)
24
PHOT
Photoelectric cell input
25
BAR
Safety edge sensor input
26
OPEN
Opening control point only
31-32
Primary transformer 230 V~
33
N
Neutral single-phase 230 V~, 50-60 Hz power supply
34
L
Live single-phase 230 V~, 50-60 Hz power supply
aerial wiring
For optimum reception, the aerial must not be cut
and must be as far away as possible from the power
supply terminal blocks and wires. The aerial must
always be installed at a height and must be visible
from a distance.
Do not fit the aerial to a metal post or behind a wire
fence.
Cut the coaxial cable if it is too long. Shortening the
cable will improve the signal (a coaxial wire which is
too long, extended or connected with an insulating
screw joint will distort the signal).
The mounting plate is an active component of the
aerial. It must not be removed or modified.
5 mm
15 mm
a
b
P2
10
11
a
b
DX
SX
Summary of Contents for Elixo 500