memorising the remote controls
to memorise a remote control:
Press the PROG button on the control unit for 2
[1]
seconds. The red indicator light will come on.
Press a channel on the remote control to which the
[2]
motorisation will be linked within 2 minutes. The
red indicator light flashes, the remote control has
been memorised.
If this procedure is carried out using a channel which
has already been memorised, this channel will be
cleared.
to add other remote controls
: repeat the above
procedure.
to add a telis type remote control
:
Press the PROG button on the control unit for 2
[1]
seconds. The red indicator light will come on.
Press the PROG button on the back of the Telis.
[2]
This must be done within 2 minutes. The red
indicator light flashes, the remote control has been
memorised
to exit programming mode without memorising a
remote control
: briefly press the PROG button on the
control unit.
self-learning
- The gate’s travel self-learning is essential when commissioning the motorisation.
- The gate must be closed before self-learning is started.
- During self-learning, the obstacle detection function is not active. Remove any objects or obstacles and do not
allow any persons near or inside the operating range of the motorisation.
- To carry out an emergency stop during self-learning, use a memorised remote control.
Before beginning self-learning
Ensure the rail is clean.
Manually move the gate to the closed position.
re-engage the motorisation:
Turn the release handle to the left.
[1]
Move the gate manually until the drive mechanism re-locks.
[2]
Turn the key a quarter of a turn to the right.
[3]
suC (closing end limit activated) should be displayed on the moto-
risation screen.
if suo (opening end limit activated) is displayed, check the
motorisation wiring (see pg. 7).
start self-learning
Self-learning comprises 2 cycles (1 cycle = 1 o 1 closing):
The 1st cycle is carried out without slowing down and enables the
•
motor to memorise the gate’s entire travel.
The 2nd cycle includes slowing down in order to establish the
•
minimum torque value needed for movement of the gate.
Press the OK button on the control unit twice to access the menus.
[1]
Use the + and - buttons on the control unit to access the AutoSet
[2]
menu.
Press the OK button to confirm. Self-learning has started. The gate
[3]
must complete 2 full cycles.