Copyright © 2008 Somfy SAS. All rights reserved.
9
EN
Elixo 500 24 V
if self-learning is correct, ok is displayed on the motorisation screen.
if self-learning has failed, ko is displayed on the motorisation screen.
Check the following before restarting self-learning:
the gate runs correctly,
•
there is nothing obstructing the photoelectric cells (if fitted).
•
If self-learning is interrupted, return the gate to the closed position and restart self-learning.
If the slowing down speed is subsequently changed, self-learning must be carried out again.
At temperatures below -5°C, there is a risk of spurious detection of obstacles. Please contact Somfy technical
services (number on the back of this guide) so that specific parameter setting can be carried out on the motor.
at this staGE iN thE iNstallatioN, thE motorisatioN is oPEratioNal.
See pages 2 and 3 in the user’s manual.
24 V integrated flashing amber light
(ref. 9 014 552)
Photoelectric cells
With autotest
Without autotest
24V
ac/dc 0V C NC NO
1 2 3 4 5
1 2
24V
ac/dc 0V
CR
CE
24V
ac/dc 0V C NC NO
1 2 3 4 5
1 2
24V
ac/dc 0V
CR
CE
Activate the cell autotest function: tESt Phot to ON in the LoGIc
menu.
Deactivate the cell autotest function: tESt Phot to OFF in the LoGIc
menu.
motorisatioN oPEratioN
CoNNECtiNG additioNal dEviCEs
Summary of Contents for Elixo 500
Page 16: ...14 Copyright 2008 Somfy SAS All rights reserved EN Elixo 500 24 V ...
Page 30: ......
Page 31: ......
Page 45: ......
Page 59: ......