background image

SOFTWARE

Somfy SDN PoE Gateway Application

*When possible, install as Administrator – Download the latest version at: 

https://www.somfypro.com/services-support/software

Windows 7 PC or higher (firewalls must be disabled while using)

HARDWARE

Unshielded Twisted CAT-5e or higher TIA-568B with Plastic RJ-45 Connectors

PowerWise™ 1G 4PPoE Indoor/Outdoor Cable recommended

Power over Ethernet Switch (Must support IEEE 802.3bt & LLDP)

Cisco Catalyst® CDB-8U Switch with Cisco Power Supply: CDB-MNT-FLEX-C14 (Non-Plenum) 

or

CDB-MNT-FLEX-DIR (Plenum)

Cisco Catalyst® 3850 Switch with Cisco Power Supplies: C3KX-PWR-715WAC 

and

C3KX-PWR-1100WAC

SDN Power over Ethernet Gateway

Gateway  #1860326

Gateway & Motor Adaptor Kit  #1870445 (Includes Motor Adaptor #9025010)

PoE Gateway to Motor Adaptor

PoE Gateway to Motor Adaptor  #9025010 (Included with Gateway Kit)

PoE Gateway to Motor & Keypad Adaptor  #9025011 (Not included with Gateway)

SDN Low-voltage Motor Cable

Non-Plenum Rated  US: #9020126 Canada: #9020452

Plenum Rated US: #9020127 Canada: #9020453

SDN RS485 DC Motor with Data & Power Pigtail

Sonesse® 30 [ST-30] DC Motor Data & Power Pigtail  #9020261 (Not included with Motor)

Sonesse® ULTRA 50 [ST-50] DC Motor Data & Power Pigtail  #9020004 (Included with Motor)

DC Drapery Adaptor for PoE Gateway #9025012 (Included with Irismo Enclosure Kit #1870282) 

OPTIONAL HARDWARE

PoE Gateway Motor Daisy Chain Adaptor #9020451

March 2019 – Rev C

The Somfy Digital Network™ Power over Ethernet (PoE) Gateway is a low-voltage power distribution and 

network-connected module that utilizes PoE technology to power and control 24V DC RS485 Motors.

The device supports both Somfy Synergy™ API and CoAP Digital Building API

compatible with Molex Transcend® Network Connected System.

R E Q U I R E M E N T S

Ethernet Input

Power & Data from PoE Switch

SDN Output

Power & Data to Motors

LED BEHAVIOR:

ACT

Solid Green 

LINK

Blinks Amber

POWER

Solid Green

C O N N E C T I O N S   &   L E D s

I. OVERVIEW

3 of 15

Summary of Contents for Digital Network 1860326

Page 1: ...PROGRAMMING GUIDE SOMFYDIGITALNETWORK POWEROVERETHERNET PoE GATEWAY...

Page 2: ...ONFIGURATION COMPUTER SETTINGS APPLICATION SETTINGS IV COMMISSIONING 9 GATEWAY DISCOVERY GATEWAY CONFIGURATION MOTOR CONFIGURATION MOTOR GROUP ASSIGNMENT MOTOR CONTROL REPORTS HELP APPENDIX 14 A FIRMW...

Page 3: ...aptor 9025011 Not included with Gateway SDN Low voltage Motor Cable Non Plenum Rated US 9020126 Canada 9020452 Plenum Rated US 9020127 Canada 9020453 SDN RS485 DC Motor with Data Power Pigtail Sonesse...

Page 4: ...with ST 30 ST 50 Data Power Pigtails 7 DC MOTOR DATA POWER PIGTAIL A SONEESE 30 ST 30 DC MOTOR DATA POWER PIGTAIL 9020261 B SONESSE ULTRA 50 ST 50 DC MOTOR DATA POWER PIGTAIL 9020004 C DC DRAPERY ADA...

Page 5: ...TO ST 30 ST 50 or DC DRAPERY ADAPTOR TO POE GATEWAY TO ANIMEO IP DECOFLEX KEYPAD Add a Keypad or daisy chain up to four Motors per PoE Gateway Irismo Motors are not compatible with the Daisy Chain Ad...

Page 6: ...ess Enter NOTE The above command will vary according to the Cisco switch model and ports available Switch config if range type no storm control multicast level 50 00 then press Enter Switch config if...

Page 7: ...to the computer ethernet port and network switch on the same network as the PoE Gateway or connect over Wi Fi on the same network 2 Go to the Network and Sharing Center then open Change Adapter Setti...

Page 8: ...View Debug Window Set to Enable when requested by Somfy Support for diagnostics Batch Firmware Update See APPENDIX A of this guide to perform Gateway firmware updates 4 Click Save to apply all settin...

Page 9: ...y Settings which includes the following options Remove Removes Gateway from the current Devices page Gateway will reappear in next Search if connected Restart Power cycles the Gateway Wink Jogs all tu...

Page 10: ...between 0 and 100 Get retrieves all recorded Intermediate Positions Set records the current Motor position to a selected slot Goto moves Motor to selected Intermediate Position Erase removes an indivi...

Page 11: ...g Priority 1 4 In the example above Group 1 will move Motor 1 first Motor 2 second Motor 3 third and Motor 4 last A red dash will unassign the Motor from a Group NOTE The PoE Gateway allocates power t...

Page 12: ...order of Priority Down arrow moves the Grouped Motors to the lower limit in order of Priority X stops all moving Motors from moving remaining Motors do not move Stop and Align stops Motors that are i...

Page 13: ...tegration Report csv documents all details necessary for third party integration Each Gateway will list in order by IP address and the Motors will list in the same order shown in the software Use Micr...

Page 14: ...have successfully updated 14 of 15 NOTE Thereare2methodstoperformGatewayfirmwareupdates a batchfirmwareupdateorindividualfirmwareupdate Bothmethodsrequirea wirednetworkconnection Gotohttps www somfypr...

Page 15: ...eens Somfy motorization systems are easily integrated with security HVAC and lighting systems providing total home or building automation FOR QUESTIONS OR ASSISTANCE PLEASE CONTACT TECHNICAL SUPPORT 8...

Reviews: