M O T O R G R O U P A S S I G N M E N T
2. The Group field displays Groups (1-5) for this Gateway – Click a Group from the column and edit the name
to identify each individual Group.
3. The Motor Label of each connected Motor is displayed as programmed and in order listed on the Devices
page – Use the drop-down to assign Motors to a Group using Priority (1-4).
•
In the example above, Group 1 will move “Motor 1” first, “Motor 2” second, “Motor 3” third, and “Motor 4” last
•
A red dash will unassign the Motor from a Group
NOTE: The PoE Gateway allocates power to Motors allowing (2) Sonesse 30 RS485 Motors to operate at a time and only (1)
Sonesse ULTRA 50 DC RS485 or (1) Irismo 35 Mini DC to operate at a time
4. Click Save to set all priorities.
1. Click Groups on the Devices page to open the
Group Priority
window.
11 of 15
NOTE: Each PoE Gateway has a maximum of 5 Groups and allows up to 16 Motor Group assignments.