HYDRA-EXTRACTOR
®
OVERFLOW AND PULPER DRAIN:
1) Install 1-1/2" pipe from the Hydra-Extractor
®
overflow to floor drain (
DO NOT REDUCE
).
2) Install 2" pipe from the Pulper drain to floor drain (
DO NOT REDUCE
).
RETURN PIPING FOR UNITS WITH A TRAY FEED ONLY:
1) Install the pre-piped return water assembly onto the return pump (if not already factory
installed) (see enclosed diagram and Installation Drawings).
2) Install one side of the provided tubing over the return water elbow on the feed tray and
the other side onto the pump return water assembly (if not already factory installed).
3)
Install the provided hose clamps at each connection.
RETURN PIPING FOR UNITS WITH A TROUGH:
1)
Pipe from the return pump to the supplied trough end flush nozzle and silver saver
connections as well as to the optional trough nozzles as shown in the trough detail on the
Installation Drawing using the provided throttling gate valves
NOTE:
All Pre-Piped Assemblies are hand tightened for shipping purposes only.