SHUTDOWN PROCEDURES -
The following shutdown procedures must be followed
prior to performing necessary cleaning and maintenance duties.
1. Allow the Pulper to operate approximately fifteen minutes after the last waste
has been fed.
2. Depress black “
TIMED STOP
” pushbutton once to engage spray rinse system,
system will then time out on its own. The Pulper will stop when the shutdown
timer has timed out.
3.
Press “
DRAIN EMPTY
” pushbutton on panel door to drain system. This
pushbutton will
DRAIN ONLY
, you must press
GREEN
start button to close
drain. This will pre-fill the system again.
4.
Lock in the
STOP
button lock and turn power off to perform any cleaning or
maintenance.
5.
Refer to the applicable Pulper and Hydra-Extractor
maintenance sections of
this manual for daily, weekly and long term shutdown cleaning procedures and
maintenance instructions.
***To ensure all food waste is removed from the extractor, you can use Styrofoam plates
as a cleaning agent for the unit. The Styrofoam will force out the majority of food waste
leaving only Styrofoam. Run the plates as you would any waste, and continue until
nothing but Styrofoam exits the extractor. We do not recommend using cardboard as it
will dry out and create a very hard obstruction in the extractor which could cause motor
overload on restart.***
*Print sequence of operation on next page for display for operators.*
Summary of Contents for SPC-75S
Page 12: ...Installation ...
Page 16: ...MOUNTING DETAIL OF TROUGH ...
Page 21: ...FOR REFERENCE ONLY ...
Page 22: ...Start Up ...
Page 26: ...Operation ...
Page 32: ...CLEANING YOUR SYSTEM ...
Page 38: ...MAINTENANCE ...
Page 49: ...TROUBLESHOOTING ...
Page 56: ...REPLACEMENT PARTS EXPLODED VIEWS ...
Page 57: ......
Page 60: ......
Page 62: ......