into position. Turn the feeder off.
5.
Replace the cover and the three screws except the one
over the "IN" tube fitting. Leave this screw loose enough
to turn tube fitting for adjustment. NOTE: To obtain
maximum tube life, the tube assembly must ride in the
center of the rollers. To center the tube assembly on the
rollers, set the feed rate dial on #10, turn the feeder on,
turn the "IN" tube fitting not more than 1/8 of a turn in the
direction which the tube must move. Observe the tube
assembly. It should move toward the center of the rollers.
If the tube moves further from the center of the rollers,
turn "IN" tube fitting in the opposite direction until the
tube centers. Turn the feeder off and tighten the tube
housing cover screws left loose.
Major Components
Disassembly/Assembly Instructions
No tools are necessary
TO DISASSEMBLE:
1.
Unplug feeder power cord and
remove chemical lines.
2.
Grasp the mechanical feed rate
control section and turn it
clockwise until it stops. Pull
straight off shaft.
3.
The tube housing complete
can be removed from the feed
rate control in the same manner
TO ASSEMBLE:
1.
Align the mechanical feed rate control with the flat
on the gear motor shaft. Push on straight. Turn the
feed rate control until mounting rivets on gear motor
fit into the keyhole slots in the feed rate control unit.
Turn the feed rate control unit counter-clockwise until
the snap lock engages. Insure the feed rate dial
pointer is on the top.
2.
Align the tube housing complete with the flat on
the feed rate control output shaft. Push on straight.
The mounting rivets will fit into the keyhole slots on
the back of the tube housing complete.
Summary of Contents for SPC-75S
Page 12: ...Installation ...
Page 16: ...MOUNTING DETAIL OF TROUGH ...
Page 21: ...FOR REFERENCE ONLY ...
Page 22: ...Start Up ...
Page 26: ...Operation ...
Page 32: ...CLEANING YOUR SYSTEM ...
Page 38: ...MAINTENANCE ...
Page 49: ...TROUBLESHOOTING ...
Page 56: ...REPLACEMENT PARTS EXPLODED VIEWS ...
Page 57: ......
Page 60: ......
Page 62: ......