CIE-H10A User Manual Ver. 1.1
- 18 -
⚫
Setting of CIE-H10A
ezManager is the management tool for parameters of CIE-H10A. This application is
only for MS Windows and this is comfortable to use because it does not need
installation process.
First, search your CIE-H10A via network. All the values of parameters are set to the
default values in the factory. To apply it to your system, proper values should be set
via ezManager.
Default values of some major parameters are listed on the table below. To make the
test simple, keep these values during the test.
Parameter
value
Network
Local IP Address
10.1.0.1
Subnet Mask
255.0.0.0
Option
Telnet
Checked
IP Address Search
Checked
Serial Port
Serial Type
RS232
Baud Rate
19,200bps
Parity
NONE
Data Bits
8
Stop Bit
1
Flow
NONE
Communication Mode
T2S
–
TCP Server
Local Port
1470
I/O Port
Web (HTTP)
Checked
Web (HTTP) Port
80
Modbus/TCP
Checked
Master/Slave
Slave
Connection Mode
Passive Connection
Multiple Connection
1
Local Port
502
Table 2-1 default values of some major parameters
You can download the latest version of ezManager on the [Download] >> [Utility] page
on our website.