AIR PROPERTIES - Output correction due to air properties.
Specified outputs presuppose the following air properties (as per ISO 3046):
Air pressure:
1000 mbar (750 mmHg)
Air temperature:
25ºC
Humidity: 30%
If the air deviates from these values, correction factors (in %) are found in the graphs below. Use the correction factors in
“calculation of engine output”
Output co
rre
ctio
n (%
)
Output co
rre
ctio
n (%
)
Temperature (ºC)
Air Pressure (mbar)
Graph
3
Graph
4
Effect of intake air temperature on engine output.
+25ºCis reference temperature (0%).
Effect of air pressure on engine output. Normal value
is1000 mbar (750 mm Hg) (0%).
_________
NORMALLY ASPIRATED
- - - - - TURBOCHARGED