Systems and schedulded
maintenance
Solé, S.A. C-243 b, km 2 · 08760 Martorell (Barcelona) ·Tel. +34 93 775 14 00 · www.solediesel.com · [email protected]
32
Operator’s Manual Marine
generators sets
Type 1 installation. When between water injection point of wet exhaust and waterline is
minimum 150 mm.
Type 2 installation. When between water injection point of wet exhaust and waterline
there is less than 150 mm or the point of injection is below waterline.
The wet exhaust is the genset’s standard equipment. If you want dry exhaust, which is an
optional equipment, contact with our dealers.
Maintenance task. Air filter inspection
Genset is provided with an intake air filter. Examine the element and
housing for damage. Replace the complete air filter if necessary.
It is important to ensure that the combustion air is freely supplied
and freely expelled from the area.