ID-DCU-MARINE-2.2.1
, ©ComAp – January 2015
- 157 -
ID-DCU-MARINE-2.2.1r2.pdf
ID-RPU
Power supply
Voltage range
8 - 36V DC
Binary inputs
Number of inputs Sd1
– Sd5
5 (broken wire detection, 10 k
required)
Input resistance
1 k
Input range
0 - 5 VDC
Switching voltage level for close contact indication
0 - 1,5 V
Max voltage level for open contact indication
3 - 4,5 V
Voltage range for broken wire indication
4,5 - 5 V
Resistance limit for broken wire detection
20 k
Emergency stop input (normally closed)
1 (no BW detection)
Speed pick-up input
Type of sensor
magnetic pick-up (connection by
shielded cable is recommended)
Input impedance
10 k
Minimum input voltage
2 Vpk-pk (from 4 Hz to 4 kHz)
Maximum input voltage
50 Veff
Minimum measured frequency
4 Hz
Maximum measured frequency
10 kHz (min. input voltage 6Vpk-pk)
Frequency measurement tolerance
1,5 %
Solenoid driver (power) outputs
Galvanic separated
separate terminals for ± supply
Number of outputs
2 (Fuel solenoid, Stop solenoid)
Maximum current
8 A DC (one channel only)
Maximum current
12 A DC (both channels together)
Supply voltage range
8 - 36 VDC
Protections
OFF-STATE
Broken wire (open circuit) detection
ON-STATE
Short circuit
Overload (switch-overheat detection)
Lost of power supply indication
Binary outputs
Number of outputs
2 (fix function: Warning and Shut down)
Maximum switching voltage
36 VDC
Maximum current
0,5 A
ID-SCM
Nominal power supply
24 VDC
Power supply range
8
– 36 VDC
Max consumption
100 mA
Mechanical dimensions:
108 x 108 x 25 mm,
Interface to controller
direct mounted (SUB25)
Binary inputs and outputs
no
Analog input
no
Operating temperature
-30..+70
o
C