General description
This guide provides general information on how to operate the InteliDrive controller. More detailed
information is available in the User guides for ID-DCU Marine or ID-DCU Industrial.
InteliDrive ID-DCU Industrial and ID-DCU Marine engine controllers controls, monitors and protects the
engine in single or variable speed operational modes (ID-DCU-Industrial) and propeller, emergency, auxiliary
and harbor modes (ID-DCU-Marine). The controllers can communicate with Engine Management System via
the CAN serial line using standard J1939 or another (KWP2000) communication protocol.
InteliDrive controllers are equipped with a powerful graphic display with icons, symbols and bar-graphs and
panel buttons for intuitive operation.
InteliDrive ID-DCU-Marine central unit together with ID-RPU provides redundant engine control. Switches
itself to the backup mode in the case of controller failure, protects engine using its own Shut down and
Emergency stop inputs and Fuel, Stop outputs. Monitors power supply, switches to the secondary power and
measures also the secondary RPM.
Engine functions
Engine sequencing and control (start/stop, warm-up and cool-down, pre-lubrication etc.)
Different operational modes – single or variable speed (ID-DCU-Industrial) and emergency, auxiliary,
harbor or propulsion (ID-DCU-Marine)
Engine monitoring and protections (2 or more level analog inputs protection, adjustable delays)
Speed measurement from magnetic pick-up or from ECU (+ redundant channel – ID-DCU-Marine
only)
Running hours meter, number of starts counter
Configurable 14 Binary inputs and Outputs and 8 Analog inputs
Setpoints are adjustable via InteliDrive
panel or via PC software
3 level password protection
On screen Alarm and ECU Alarm indication
Event and time driven engine history for back tracing
Two or more languages selectable in controller
Communication
RS232 / Modbus RTU
Analog or GSM modem
Engines with Engine Electronic Control Unit: J1939, J1587, KWP2000
Extension units for more I/O and Remote Display panel
Physical
180x120 mm front panel mounted case
Graphic back-lit LCD display 128x64 pixel resolution with icons and bar graphs
LED status indicators / Lamp test
Available modules
ID–RPU Redundant Protection Unit (at ID-DCU-Marine only)
ID-SCM Speed control module (at ID-DCU-Industrial only)
IS-AIN8 Extension module with 8 analog inputs
IS-BIN16/8 Extension module with 16 binary inputs and 8 binary outputs
IGS-PTM Extension module with 4 analog inputs and 8/8 binary in/outputs
IGL-RA15 Extension module with 15 indicating LED