Model: A1-Hybrid-8.6-US
No. of MPPT/Strings Per MPPT
DC Operating Voltage Range
Max.DC Current per MPPT
Max.DC Power
Nominal AC Voltage
Max.Continuous Power
Max.Continuous Current
Nominal AC Frequency
4/1
10A
10320W
60Hz
0.8 Leading- 0.8 Lagging
105-500Vdc
AC Power Factor Range
GRID OUTPUT/ INPUT
LOAD OUTPUT
(
WITH
AUTOTRANSFORMER
)
Nominal AC voltage
Nominal AC frequency
60Hz
Max.Continuous AC current
Max.Continuous AC power
41A
9460VA
36A
8600VA
Nominal AC voltage
Max.Continuous AC current
44A
PV INPUT
GRID SUPPORT UTILITY-INTERACTIVE
TRANSFORMERLESS INVERTER
GENERATOR INTPUT
120/240 Vac split phase
59.3Hz-60.5Hz
Operating Frequency Range
120/240 Vac split phase
120/240 Vac split phase
BATTERY
Battery Type
DC Operating Voltage Range
Max. Charge / Discharge Current
Li-ion
84-432Vdc
25A/25A
Nominal AC voltage
Nominal AC frequency
60Hz
Max.Continuous AC current
120/240Vac split phase
44A
OTHER
Enclosure Type
Type 4X
Inverter
SN:
SolaX Power Network Technology (Zhe jiang) CO., LTD.
ADD:No.288 Shizhu Road,Tonglu Economic Development Zone,
TEL: +86 571 5626 0011 E-mail: [email protected]
www.solaxpower.com
Dongxing District,Tonglu City, Zhejiang Province, China.
612.01336.02
Nominal DC Voltage Range
360Vdc
Operating Temperature
-4
℉
~+140
℉
no derating below 113
℉
LISTED
intergrated
PV AFCI
TYPE 1
UL 1741 / UL 1699B
UL 62109-1 / CSA107.1
272687
Introduction
Technical Data
3.6 Identification of A1-Hybrid Series
1 . Every A1-Hybrid series product corresponds to a unique serial number. A1-
Hybrid series serial number is divided into five parts: type (2 bits)+ power (4 bits)+
year/month (2 bits)+ work order number (3 bits)+ stream number (3 bits) a total of
14 bits.
2 . Standard A1-Hybrid series number preparation rules are as follows:
A1-7.0-US
A1-6.0-US
0720
AH
E
7
0
0
0
1
Modle
Power
Year
Month Work order number
Serial number
0
0
1
AH: Type A1-Hybrid ---- AH: A1-Hybrid.
0720: Power ----720 x 10 W; 0840:840 x 10 W; 1032:1032 x 10 W...
E: Year ------ D:2018 (A:2014; B: 2015......)
7: Month ------ July (October :A, November ;B, December......)
001: Work order number---- 001:001~999 (Monthly zero clearing)
001: Serial number---- 001:001~ZZZ (Clear each work order).
4 Technical Data
4.1 DC Input
4.2 Grid
7200W
A1-Hybrid-6.0-US
Model
A1-Hybrid-7.0-US
A1-Hybrid-7.6-US
A1-Hybrid-8.6-US
8400W
9120W
10320W
6000VA
7000VA
7600VA
8600VA
9460VA
120 / 240 Vac split phase(211 Vac - 264 Vac )
60 ( 59.3~60.5)
0.8 leading...0.8 lagging
< 3%
optional
765Apeak/5ms, 46Arms/cycle
Model
6600VA
7700VA
8360VA
A1-Fit-7.0-US
A1-Fit-7.6-US
A1-Fit-8.6-US
A1-7.0-US
A1-7.6-US
A1-8.6-US
A1-6.0-US
A1-Hybrid-6.0-US
Model
A1-Hybrid-7.0-US A1-Hybrid-7.6-US
A1-Hybrid-8.6-US
Model
Parameter
Serial Number Identification
2/1
360-500Vdc
280-500Vdc
304-500Vdc
258-500Vdc
25A
28A
29A
32A
32A
35A
36A
41A
4.3 AC Load
120 / 240 Vac split phase (211 Vac - 264 Vac )
A1-Hybrid-6.0-US
Model
A1-Hybrid-7.0-US A1-Hybrid-7.6-US A1-Hybrid-8.6-US
60Hz
6000VA
7000VA
7600VA
8600VA
25A
29A
32A
36A
200 Apeak /10ms, 34Arms/cycle
3600W
600Vdc
360Vdc
105-500Vdc
10A/per MPPT
12.5A
150Vdc
3/1
3/1
4/1
Max. Recommended DC Power [W]
Max. DC Power per MPPT [W]
Max. DC Voltage [V]
Nominal DC Operating Voltage [V]
Operating Typical Voltage [V]
Full Voltage Range Rating [V]
Max. Input Current per MPPT [A]
Max. Short Circuit Current [A]
System Startup Voltage [V]
No. of MPPT / Strings per MPPT
Rated Grid Voltage (range) [V]
Operating Frequency Range [Hz]
Rated AC Current @240V [A]
Displacement Power Factor
Total Harmonic Distortion (THD)
Load Control
Max. Output Fault Current
[A] Duration [ms]
Max. AC Current @240V [A]
Rated AC Power [ VA]
Max. apparent AC Power [ VA]
Nominal AC Output Voltage Range [V]
Max. AC Output Fault Current [A] and
Nominal AC Output Frequency [Hz]
Maximum Continuous AC Output Power
Max. Continuous Output Current [A]
Duration [ms]
12
13