30
SOWING ELECTRONIC CONTROL
Sequence of 10 runs
For use with 4-meter seed driller and 10-meter seed spread-
er, or with 8-meter seed driller and 20-meter seed spreader
(2+2 left outlets will close on runs 4 and 7 and, 2+2 right out-
lets will close on runs 2 and 9). At the beginning of run 1, it is
necessary to turn right at the end of the first road.
NOTE:
TO RUN LEFT AT THE END OF THE FIRST
ROAD, MOVE THE MARKER FORWARD UNTIL
NUMBER 6 BEFORE START SOWING.
1
2
3
4
5
6
7
8
9
10
15 metres
4 runs for 15-meter seed spreaders
6 m
10 runs for 6-meter seed drillers
O/P2
(R/H)
O/P1
(L/H)
O/P1
(L/H)
O/P2
(R/H)
Fig. 75
Sequence of 18 runs
For use with 4-meter seed driller and 18-meter seed spread-
er. (2+2 left outlets will close on runs 3 and 16 and, 2+2 right
outlets will close on runs 7 and 12). At the beginning of run 1,
it is necessary to turn right at the end of the first road.
NOTE:
TO RUN LEFT AT THE END OF THE FIRST
ROAD, MOVE THE MARKER FORWARD UNTIL
NUMBER 10 BEFORE START SOWING.
The monitor will whistle on the road-marking run.
27 metres
6 m
4 runs for 27-meter seed spreaders
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1
O/P2
(R/H)
O/P1
(L/H)
O/P2
(R/H)
O/P1
(L/H)
18 runs for 6-meter seed drillers
Fig. 76
Select the type of sequence
1-
Select the
channel.
2-
Push
entering into mode 1.
After 5 seconds, the first two digits flash indicating the
type of sequence:
‘SY’
= Symmetrical
‘AL’
= Asymmetrical left
‘AR’
= Asymmetrical right
‘AS’
= Special asymmetrical with 10 and 18 sequences.
3-
Keep at the same time
and
for modifying the
sequence.
Fig. 77