26
SOWING ELECTRONIC CONTROL
C1 C2 C4 C5 C6
NEUMASEM
Ha 0
0/1
Fig. 63
Left foldable part
closing
Display
Right foldable part
closing
Micro-dosage
Left foldable part
closing control
Programming
Total 1 and 2 areas
Central button
Channel change
Value and digit change
Self-calibration programming
Resetting the areas
Total cut off
Hopper level channel
selected
Right foldable part
closing control
8. SOWING ELECTRONIC CONTROL
8.1 CONTROL PANEL, DESCRIPTION
The factory default settings of the monitor are for the seed
driller on which it is mounted. Therefore, it is not necessary
to program it, just visualize the values.
The display shows 6 different channels or readings, and 3 sit-
uation-indicating arrows.
C1
indicates the running speed in m/sec.
C2
indicates two different hectares (for instance, a partial
one and a total one).
C3
unable.
C4
indicates the turbine rotational speed in rpm.
C5
indicates the distributor shaft rotational speed in rpm.
C6
indicates when the seed level in the hopper is too low.
By default, the reading shown on the display is the running
speed. When there is any anomaly in any reading, the dis-
play shows a flashing
«Alarm»
indication, a sound alarm is
triggered and the channel where the anomaly was produced
activates. This alarm will not disappear until the anomaly is
not solved.
For visualizing the regarding reading, push the central but-
ton and move the corresponding channel. After 10 seconds,
the reading automatically goes back to C1.
8.2 RUNNING SPEED -C1
Select the channel by means of the central button. The alarm
triggers under the 2.6 Km/h. This alarm can be deactivated
entering in the programming mode 2.
Speed sensor calibration
The theoretical calibration is achieved entering the calibra-
tion factor in the programming mode 2, according to the
value indicated in the following chart.
MACHINE MODEL
6 metres
7 metres
CALIBRATION FACTOR
1,365
1,365
Select the speed channel (C1)
1-
Push
for entering into the mode 1. Keeping it pushed,
push the central button
for changing the digit to
modify.
2-
Keep the central button pulsed during various seconds for
modifying the value of the flashing digit.
3-
The monitor will go back to the normal position when
stop pushing the buttons.