27
SOWING ELECTRONIC CONTROL
NOTE:
THERE IS A MORE PRECISE SELF-CALI-
BRATION MODE FOR THE AMOUNT OF IMPULS-
ES, WHICH REQUIRES A FIELD TEST.
Speed sensor self-calibration
1-
Mark 100 m
2-
Select canal 1 (speed).
3-
Press
and keep it pressed
.
The indication Auto will appear in the display. Stop
pressing.
4-
Run until the 100 meters marked. The monitor counts the
sensor impulses.
5-
When finishing, press again
.
The monitor has already memorized the amount of impulses.
8.3 TOTAL AREA /
SEED DRILLER WIDTH - C2
It is possible to mark two total and independent areas.
Visualization of total area.
1-
Select canal 2.
2-
Push
to see the total area 1 and total area 2 «tot.1»
and «tot.2». The screen will show «tot.1» at first and then
its value in Ha.
Resetting the total areas
1-
Select canal 2.
2-
Push
for visualizing.
3-
Push the button longer than 5 seconds
.
Programming works width
1-
Select canal 2 of area.
2-
Push
the button longer than 5 seconds until a width
value appears on the screen and. holding it pressed, push
the central button for modifying the flashing digit.
3-
Push the flashing digit longer than 3 seconds for modify-
ing its value.
4-
Stop pushing the buttons for going back to the normal
position.
Working in micro mode
When working with the distributor in micro-dosage mode
(for small hoppers and small quantities) it is necessary to
push the button
longer than 3 seconds until the arrow
indicating the micro mode appears on the screen. In this
case, the monitor will keep the actual work speed and area.
For going back to the normal operation position, once again
push
longer than 5 seconds until the indicating arrow
disappears.
8.4 CONTROL PANEL WITH TRACK MARK-
ER (OPTIONAL)
SEL
STOP
Ha 0
MICRO
NEUMASEM PLUS
C1 C2 C3 C4 C5 C6
Fig. 64
Display
Total closing
Micro-dosage
Total closing control
Programming
Total 1 and 2
areas
Central button
Channel change
Value and digit change
Closing of foldable parts
Programming
Self-calibration
Resetting the areas
Foldable parts
closing control
Channel
The factory default settings of the monitor are for the seed
driller on which it is mounted. Therefore, it is not necessary
to program it, just visualize the values.
The display shows 6 different channels or readings, and 3 sit-
uation-indicating arrows.
C1
indicates the running speed in m/sec.
C2
indicates two different hectares (for instance, a partial
one and a total one).
C3
track marker.
C4
indicates the turbine rotational speed in rpm.
C5
indicates the distributor shaft rotational speed in rpm.
C6
indicates when the seed level in the hopper is too low.