13. SETTING INSTRUMENT STATION
3. Select "Setting".
4. Set for resection measurement.
Set the following items:
(1) RL observation (F1/F2 Obs):
Observe every point in Face 1 and 2 in resection.
" 13.2.3 RL observation in resection measurement"
Set "F1/F2 Obs" to "Yes" when performing RL
observation.
(2) Display
σ
Z (Z)
Set "Z" to "On" to display standard deviation
σ
Z in the
instrument station coordinate calculation screen and
result (standard deviation) screen of coordinate
resection.
• Press
[
σ
NEZ]
to display standard deviation which
describes the measurement accuracy. Press
[NEZ]
to
return to the instrument station coordinate screen.
•
σ
Z can be displayed by pressing
{
}
in the result screen in
which
is
displayed.
Choices of the setting are as follows (*is the default setting):
• RL observation: Yes / No *
• Display
σ
Z: On* / Off
Resection.
NEZ
Elevation
Setting
Setting
F1/F2 Obs
Z
:
No
: On
9 . 9 9 9
RESULT
N E Z
OK
0 . 0 0 2 2 m
0 . 0 0 0 7 m
0 . 0 0 1 4 m
RESULT
N E Z
OK
1 s t
2 n d
3 r d
- 0 . 0 0 1 0 . 0 0 1
- 0 . 0 0 1 0 . 0 0 1
0 . 0 0 5 0 . 0 1 0
RE_CALC
OMIT
RE_MEAS
ADD
1 s t
2 n d
3 r d
- 0 . 0 0 1
- 0 . 0 0 3
0 . 0 0 5
RE_CALC
OMIT
RE_MEAS
ADD
Z