193
33. CHANGING THE SETTINGS
The following explains the two methods of restoring default settings:
Restoring set items to initial settings and turning power on. Initializing the data and turning power on.
• Restore the following items to the initial settings when the iM was shipped.
EDM setting, Config mode settings (including softkey arrays)
About initial settings when the iM was shipped: "33.1 Observation Conditions - Angle/Tilt",
"33.11 Allocating Key Functions"
• Initialize the data. The following data is initialized.
Data within all jobs
Known point data within memory
Code data within memory
PROCEDURE Restoring set items to initial settings and turning power on
1. Turn the power off.
2. While pressing
{F4}
and
{B.S.}
, press the power key.
3. The iM is turned on, “Default set” appears on the screen
and all items are restored to their initial settings.
PROCEDURE Initializing the data and turning the power on
1. Turn the power off.
2. While pressing
{F1}
,
{F3}
and
{B.S.}
, press the power key.
3. The iM is turned on, “Clearing memory...” appears on the
screen and all items are restored to their initial settings.
33.12 Restoring Default Settings