43
12. DISTANCE MEASUREMENT
4. Enter into the REM menu. Select "REM."
5. Sight the target.
Pressing
[REM]
starts REM measurement.
The height from the ground to the object is displayed in
“Ht.”.
6. Press
[STOP]
to terminate the measurement operation.
• To re-observe the target, sight the target, then press
[MEAS]
.
• Press
[HT]
to enter an instrument height (HI) and a target
height (HR).
• When
[REC]
is pressed, REM data is saved.
"28. RECORDING DATA - TOPO MENU -"
• Press
[HT/Z]
on the second page of the REM
measurement to display the Z coordinate for the height
from the ground to the target. Pressing
[HT/Z]
again returns
to the height display.
7. Press
{ESC}
to finish measurement and return to the OBS
mode screen.
• It is also possible to perform REM measurement by pressing
[REM]
when allocated to the OBS mode screen.
"33.11 Allocating Key Functions"
• Inputting instrument and target height: Press
[HT]
to set instrument and target height. It can be set also in
“Occ. Orientation” of coordinate measurement.
"13.1 Entering Instrument Station Data and Azimuth Angle"
REM
Occ.Orien.
REM
REM
Ht.
SD
ZA
HA-R
REC
REM
Ht.
SD
ZA
HA-R
H T
MEAS
Height
HI
HR
0.000m
0.000
m
OK