3
Configuration of the WB169-SI2 module
Configuration parameters of the WB169-SI2 module can be displayed and changed from the common computer
(PC) by one of these methods:
- with using of
”
USB-CMOS”
converter and configuration cable connected to the module;
- wirelessly, with using of
”
USB-IRDA”
or
”
BT-IRDA”
converter;
-
remotely
, by using of bi-directional communication system.
Technique of interconnection of the module with configuration computer and general rules of configuration are
described in detail in the chapter 2 of
”
Configuration of wacoSystem product family devices”
, that can be
downloaded from the producer website:
www.wacosystem.com/support/
www.softlink.cz/en/documents/
The description and meaning of all configuration parameters that can be checked and changed by cable can be
found in the section
”
Setting of WB169-SI2 parameters via configuration cable”.
Description of interconnection of the converter with PC (
”
USB-IRDA”) or smartphone (
”
BT-IRDA”) and general
rules of configuration with using of
optical converters
are described in the chapter 3 of above mentioned manual
”
Configuration of wacoSystem product family devices”. The description and meaning of the parameters that can be
changed by optical converter can be found in the section
”
Setting of parameters by using of optical converter”.
Principles and short description of communication through the
Wireless M-Bus back channel
can be found in
paragraph
”
Bi-directional communication mode”.
3.1
Setting of WB169-SI2 module parameters by configuration cable
3.1.1
List of module configuration parameters
List of all module configuration parameters can be displayed by entering of
”show”
command and pressing of
”
ENTER” key. The following list of parameters will display in the terminal window:
mon#show
----- Configuration -----
Timezone : 1
MBUS ID : 00100017
MBUS version : 5
MBUS manufacturer : SFT
MBUS medium : 7
MBUS manuf info : SI2N1
MBUS value[0] DIB : 04, VIB 13, multiplier 1, divider 1, mode falling, quick, alr: none
Leak detection periode 24 hour(s), zero periode 90 minutes
Broken pipe min. 50 pulse/10 min. during 30 minutes
MBUS value[1] DIB : 44, VIB 13, multiplier 1, divider 1, mode falling, quick, alr: none
MBUS power : 3 (20 dbm)
MBUS mode
: N2
WMBUS channel : 3 - 169,43125 Mhz
Send periode : 60 min
Send mask is 3 : I1, I2
Data will be encrypted by AES
Next send : 30 min.
No. sent : 3 msg(s)
No. recv : 0 msg(s)
Conf. version : 12
SW version 0.01, date Aug
9 2019
mon#
WB169-SI2
5