The configuration can be erased in Flash memory by using of
”clear”
command:
cfg#clear
Clearing configuration ... OK, version
This command deletes all configuration parameters from the FLASH memory, so it is necessary to set them again.
If after erasing all parameters in FLASH memory the module goes to reset, default set of parameters (configured
in the program of the device) is duplicated to FLASH memory. There is only one exception - frequency constant
keeps the actual value also after cleaning of FLASH memory by ”clean” command.
This command is recommended to use only by users with good knowledge of the system or after
consultaion with the manufacturer.
The module reset can be performed by using of
”reset”
command.
3.1.5
”
WMBUS” group commands for setting of messages
This group of commands serves for setting of Wireless M-BUS addressing of the WB169-SI2 module and for setting
of broadcasting parameters. There are following command:
mid
setting of device fabrication number (
”
M-BUS ID” – range 0 to 99999999)
manuf
setting of manufacturer code (
”
Manufacturer” - supplement of M-BUS address)
vers
setting of
”
addressing version” (
”
Version” - supplement of M-BUS address)
medium
setting of media code (
”
Medium” - supplement of M-BUS address)
info
setting device name
periode
setting of regular messages broadcasting period
power
setting of transmitting power (mW)
mode
setting of communication mode (1 - N1 mode, 2 - N2 mode)
chan
setting of frequency channel (choice from 7 options)
ekey
setting of encryption key (”.” - encryption disabled)
Variable
”
M-BUS ID”
is a serial number of the device in M-Bus standard identification system. The address is
”
read only” type for the WB169-SI2 module and cannot be changed. Assigned serial number of the module can be
displayed by
”
mid”
command (without parameter):
cfg#mid
MBUS ID : 00112233
cfg#
Variable
”
Manufacturer”
is an international code of device producer according to the M-Bus standard. The code
is
”
read only” type for the WB169-SI2 module, its value is
”
SFT” (Softlink) and it cannot be changed. Assigned
manufacturer code can be displayed by
”
manuf”
command (without parameter):
cfg#manuf
MBUS manufacturer : SFT
cfg#
Variable
”
Version”
is number of addressing version according to the M-Bus standard (each type and modification
of the device could have its own line of serial numbers). The code is
”
read only” type for the WB169-SI2 module
and cannot be changed. Assigned version number can be displayed by
”
vers”
command (without parameter):
cfg#vers
MBUS version : 101
cfg#
Variable
”
Medium”
is an international code of measured medium (water, energy, physical quantity..) according
to the M-Bus standard. The variable is editable and it is factory preset to 07 (
”
Water”). Current setting of the
medium value can be displayed by
”
medium”
command (without parameter). Medium parameter can be changed
by entering of required code of medium according to M-Bus standard (range: 0 to 255).
Example of medium code setting to ”02” value (electricity):
WB169-SI2
8