TROUBLESHOOTING HANDLING
SOFAR 1100...3300TL-G3
73
ID
Name
Description
Solution
18
HwADFaultD
CI
DC current measurement
error
19
HwADFaultV
Grid
Grid voltage measurement
error
20
GFCIDeviceF
ault
GFCI measurement error
21
MChip_Fault Master chip error
22
HwAuxPower
Fault
Auxiliary voltage error
23
BusVoltZeroF
ault
Bus voltage measurement
error
24
IacRmsUnbal
ance
The output current is not
balanced
25
BusUVP
The DC bus voltage is too
low
If the configuration of the PV
generator is correct (no ID05 error),
the possible cause may be linked to
insufficient sunlight. The inverter
automatically returns to its normal
operating state when the level of
sunlight is back to normal.
26
BusOVP
The bus voltage is too high ID26-ID27 are internal errors of the
inverter. Switch the DC switch OFF,
wait 5 minutes and then switch the
DC switch ON. Check whether the
error has been rectified. If not,
please contact the technical
support department.
27
VbusUnbalan The bus voltage is not
balanced