TROUBLESHOOTING HANDLING
SOFAR 1100...3300TL-G3
69
8
Troubleshooting handling
8.1
Troubleshooting
This section contains information and procedures pertaining to the
remedying of potential problems with the inverter.
To carry out troubleshooting, proceed as follows:
•
Check the warnings, error messages or error codes displayed on
the screen of the inverter.
If no error information is displayed on the screen, check whether the
following requirements have been fulfilled:
•
Has the inverter been set up in a clean, dry, well-ventilated area?
•
Is the DC switch set to ON?
•
Are the cables sufficiently dimensioned and short enough?
•
Are the input connections, output connections and the wiring all in
good condition?
•
Are the configuration settings for the relevant installation correct?
•
Are the display field and the communication cables correctly
connected and undamaged?
Please proceed as follows to display the recorded problems: Hold the
button down to bring up the main menu of the standard interface.
Select “2. Event list” and hold the button down to bring up the event
list.