Time-of-use Mode
If electricity is more expensive in high demand time (peak rate) & electricity is
much cheaper in low demand time (off-peak rate).
You can select an off-peak period to charge your battery. Outside the off-peak
charge period, inverter is working in Auto Mode.
If your family normally go to work/school on weekdays & stay at home on
weekends, which means the home electricity consumption is much higher on
weekends. Thus, you need to store some cheap electricity on weekends only. This is
possible using our Time-of-use mode.
In summer, if your PV system can produce more electricity than your home
electricity consumption. Then you don’t need to set an off-peak charge period to
charge your battery in summer at all. You can select an effective date (normally
winter) for Time-of-use mode in this case. Outside the effective date, inverter is
working in Auto Mode.
You can set multiple Time-of-use rules to meet your more complex requirement.
Right now we support 4 rules maximum (rule 0/1/2/3).
2.Time-of-u
se Mode
OK Set Time-of-use Mode
Rules. 0:
Enabled/Disabled
From
To
SOC
Charge
02h00m - 04h00m
070%
01000W
Effective
date
Dec.
22
-
Mar.
21
Weekday
select
Mon. Tue.
Wed.
Thu.
Fri.
Sat.
Sun.
Set Timing Mode
Changing the value of a rule can set multiple timing rules.
3.Timing Mode
OK Timing Mode
Rules. 0:Enabled/Disabled
Charge Start
22 h 00 m
Charge End
05 h 00 m
Charge Power
02000 W