![Sofar solar HYD 3000-EP User Manual Download Page 30](http://html.mh-extra.com/html/sofar-solar/hyd-3000-ep/hyd-3000-ep_user-manual_1311984030.webp)
HYD 3K~6K-EP
User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd
- 26 -
Fig 4-8
The operation information (generated energy, alert, operation status) of the inverter
can be transferred to PC or uploaded to the server via WiFi/GPRS Users can choose
to use web or APP for monitoring and viewing according to their needs. They need
to register an account and bind the device with the WiFi/GPRS SN number. The SN
number of the WiFi/GPRS shall be affixed to the package box and the WiFi/GPRS.
Web
:
https://home.solarmanpv.com
(
Recommended browser: Chrome58
、
Firefox49
、
IE9 and
above version
)
.
APP
:
Android: Go to Android Market and search “SolarMAN”.
IOS: Go to App Store and search “SolarMAN”.
SolarMAN-3.0-Web User Manual
,
Please visit the https://doc.solarmanpv.com/web/#/7.
SolarMAN-App User Manual
,
Please visit the https://doc.solarmanpv.com/web/#/14.
4.7.2 COM-Multifunction communication interface
Table 4-5 Interface description
PIN
Definition
Function
Note
1
CANH
CAN high data
Communication with lithium
battery BMS, the inverter CAN be
adaptive to lithium battery BMS to
provide CAN communication and
RS485 communication
2
CANL
CAN low data
3
485-2TX+
RS485 differential
4
485-2TX-
RS485 differential signal –
5
485-1TX+
RS485 differential
Wired monitoring or inverter
cascade monitoring
6
485-1TX-
RS485 differential signal –
7
GND-S
(DRMS) logic interfaces are
applicable to the following
safety standards:
Australia (AS4777),
European General (50549),
Germany (4105)
Logic interface connections
8
DRMS1/5
9
DRMS2/6
10
DRMS3/7
11
DRMS4/8
12
DRMS0
13
CT-
The current sensor outputs a
negative electrode
Connect current sensor of power
grid