Page 4 - 5
TL49J
TROUBLESHOOTING
Is t he
Selector Switch
, t urned on?
Motor will not start (Mains)
NO
YES
Select swit ch posit ion
& Read Operators
Manual
Are all
Emergency Stops
Reset ?
Reset
Em ergency st ops
& Read Operators
Manual
NO
YES
Has t he
Circuit Breaker
t ripped?
Reset the Circuit Breaker
& Read Operators
Manual
If further advice is
required, consult
an
Snorkel
Technician.
NO
YES
Is
the Correct Power
supply Connect ed?
Connect power supply
& Read Operators
Manual
NO
YES
!
All extensions must be a minimum of 2.5mm², and no longer than
10m, due to possible voltage drop, which will damage the motor.
Voltage Drop may be
the cause, Use a shorter
Extension lead
If further advice is
required, consult
an
Snorkel
Technician.
NO
YES
Check t he volt age at t he m ot or is
230V w hen t he m ot or is t urning?
Mot or st alling.
Working Hard, Noisy