CVR250
SECTION 2
CVR250OPS
20/10/06
www.snellwilcox.com
Version 1 Issue 4
2.2
NTSC Hue
±30°
VBI Pass (Synchronizer
Mode only)
Selectable pass or blank for each
vertical interval line
Indicators
Input Loss
Input Select LED
Reference Loss
Genlock Select LED
Information Feedback
Input Standard
Composite and SDI standard
EDH
present : error minute : error hour
Unit temperature
OK, Near limit, Over temperature
Additional
RollCall™
Functions
Single Session
Logging
Input Loss, Reference Loss, Input
Standard, EDH Errors,
Temperature
Specifications
Processing Delay
625 to 525
Linear mode = 70 ms
625 to 625
1 - 39ms (Size Off)
525 to 525
1 - 35ms (Size Off)
525 to 625
Linear mode = 58 ms
625 to 625
70ms (Size On)
525 to 525
58ms (Size On)
Return Loss: Inputs
better than 35 dB to 5.0 MHz
Return Loss: Outputs
better than 30 dB to 5.0 MHz
Return Loss: SDI Inputs
better than 15 dB at 270 MHz
Return Loss: SDI
Outputs
better than 15 dB at 270 MHz
Power
Mains Supply
115/230V 60/50 Hz 1.2 A
Power Consumption
140 W max
Mechanical
Temperature Range
0° to 40° C operating
Cooling
Axial fan
Case Type
1RU Rack Mounting
Dimensions
Overall 483 x 440 x 45 mm.
(w x d x h).
Depth from mounting face
(including unmated connectors)
415 mm.
Weight
9.75 kg
EMC Environment
This unit is intended for use in the
commercial and light industrial
environment E2.