CVR250
SECTION 5
CVR250OPS
20/10/06
www.snellwilcox.com
Version 1 Issue 4
5.8
Default Unit
On power-up the default unit will be automatically
connected, its menus retrieved and will be ready
for active control.
To define the default unit select Default Unit. Press
the button adjacent to the default text arrowhead
until the desired number is reached. (This number
is the number assigned to a particular unit in the
Auto Connect set-up) The name of this unit will
appear in the second line of text.
Select Save to save this setting.
The Clear selection sets the default unit to `None'.
Note that if no units have been assigned numbers
in the Auto Connect set-up a ? will appear in the
second line of text. Also when the numbers are
selected (in rotation) the word `None' will appear
after Default Unit when the number 15 is
exceeded. This confirms that no units have been
assigned a number.
Note that only one unit may designated as the
default unit.
BackLight
Selecting this function allows the backlighting of
the display windows to set, by rotating the
spinwheel, to the following modes:
OFF
Backlight always Off. Use this mode where
ambient light level is high.
ON
Backlight always On. Use this mode where
ambient light level is low to improve text visibility.
AUTO
Backlight will normally be On but will default to Off
after 2 minutes. The backlight will return to Auto
On whenever any front panel control is operated.
Press the button adjacent to the Save text to save
the backlight mode.
Network
This function allows the front panel to be `hidden'
from the network system. In the Hide mode this
front panel will not appear in the Module List
displayed on other control panels in the system.
SHOW
This front panel will appear in the Module List of
other control panels.
HIDE
This front panel will not appear in the Module List
of other control panels.
Min/Max Unit Addr
The front panel can only hold a maximum of 200
addresses. The Min and Max Unit Addr (Address)
function allows a range of addresses to be
configured for partial use of the network.
The
Min Unit Addr
selection sets the minimum
address.
The
Max Unit Addr
selection sets the maximum
address.
The overall range of addresses is from 1 to 255.