135
Maintenance
M2 Data Acquisition Device
Replace the battery pack with the exact replacement rechargeable nickel-metal hydride (Ni-MH)
type battery only. Do not attempt to use standard (lead/zinc) batteries as they do not provide
sufficient power to operate the Data Acquisition Device, and may leak and damage the tool.
:$51 ,1*
Risk of electric shock.
• Prior to recycling the battery pack, protect exposed terminals with heavy insulating tape
to prevent shorting.
• Disconnect all test leads and turn diagnostic tools off before removing the battery pack.
• Do not attempt to disassemble the battery or remove any component projecting from or
protecting the battery terminals.
• Do not expose the unit or battery pack to rain, snow, or wet conditions.
• Do not short circuit the battery terminals.
Electric shock can cause injury.
IMPORTANT:
Be aware of all applicable safety considerations when replacing, handling, and recycling batteries.
Refer to
"Battery Safety Guidelines‚" on page 131
for details.
z
To replace the battery pack:
1.
Press to release the hanger catch on the back of the M2 unit (
), then swing the
hanger up (180º) so that it is fully extended.
1— Hanger Catch
2— Captive Screw
Figure 15-8 M2 unit battery pack replacement
2.
Loosen the captive screw that secures the battery cover (
).
3.
Remove the battery cover.