9
4. Isolate electrical supply and connect the
transformer flying leads to the fused spur
(3A). The transformer must be located
outside the bathroom or high humidity
area. Connect the single-pin male
connectors to the twin core cable you have
supplied.
5. Push in the connectors to the transformer
terminals and connect the other end of the
cable to the terminals on the back of the
product.
1. Turn on the electrical supply at the fused spur.
2. Set the upper control switch on the fascia grille
to BLUE and lower switch to either I or II — the
fan will run.
3. Turn on the central heating system.
4. Set any room thermostat/s to maximum.
5. Set the lower heat output switch to I and the
Commissioning
upper switch to RED — the fan should run and
heat will flow within a few minutes.
6. Balance the central heating system if Space
Saver is installed on the same circuit as panel
radiators.
7. When the installation is working correctly,
remember to reset any room thermostat/s to
its normal setting.