4
Installation Guide
1. We recommend the use of a kneepad when
installing this product. Cut the opening in
the plinth to the size shown in the table. Use
method A or B
4. Isolate electrical supply and connect the
heater electric cable to the fused spur
(3A). Ensure the fused spur is not directly
above the heater and is accessible after
installation is complete.
2. Fit isolating valves (not supplied) to the
system flow and return pipes. Failure to fit
isolating valves may mean that the product is
not serviceable in the event of failure.
Connect the flexible hoses between the
system pipework and heater. Open the
isolating valves and check for leaks.
Model
Width A
Height B*
SS3 W
475mm
96mm
SS5 W
475mm
96mm
SS7 W
475mm
96mm
SS9 W
570mm
96mm
* The overall height of the grille is 100mm. Use care
when cutting the opening
3. Vent air through the bleed screw.
A
B